Skip to content
Boilers.caby ROMA Heating & Cooling

Burnham · Burnham ES2

Burnham ES2 ES28

The Burnham ES2 ES28 fires a fixed 245 MBH input for 208 MBH DOE heating capacity and a 181 MBH net AHRI rating at 85% AFUE, with a 7" draft hood and 3/4" NPT gas — the second-largest non-condensing ES2 cast-iron size.

CurrentCanadian status unknown

Key figures

Max input
245 MBH
Max CSA output
AFUE
85 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham ES2 ES28 in practice

The ES28 is the second-largest ES2 at a fixed 245 MBH input, printing 208 MBH DOE heating capacity and a 181 MBH net AHRI water rating at 85% AFUE (ES2 I&O ratings table, Doc 103780-11). It shares the 7" natural-draft draft hood with the ES27 and is a NON-condensing cast-iron boiler vented Category I into an existing lined chimney.

The ES28 ships at 518 lb (438 lb empty) with 1-1/4" NPT supply/return and 3/4" NPT gas connections, on the IQ Boiler Control System with optional outdoor-reset and LWCO cards, natural or LP gas. MAWP is 50 psi with a 30 psi shipped relief valve; supply water runs 130–220°F with a 110°F minimum return. Family dimensions reach 35" deep by 27-3/4" wide by 41" high on this size. Sizing and installation are licensed-contractor work from a heat-loss calculation.

Best suited to

  • Large homes and light-commercial loads near a fixed 245 MBH input
  • Chimney replacements where a 7" draft-hood connector matches the existing flue
  • Owners wanting maximum cast-iron capacity before the top ES29 size

Applicability and support

Model number
ES28
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham ES2 ES28 specifications
SpecificationValueNote
Input
Input245 MBHFixed input (no modulation) per the ES2 ratings table (Doc 103780-11); ratings apply to elevations up to 2,000 ft.
Output
DOE heating capacity208 MBHPer the ES2 ratings table.
Net AHRI water rating181 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15, per the ES2 ratings table.
Efficiency
Efficiency (AFUE)85 %85% AFUE — a NON-condensing rating; the ES2 is a natural-draft cast-iron boiler, not a condensing design.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
VentingCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 7" draft hoodNon-condensing, natural-draft design: NOT a direct-vent or condensing boiler. Draft hood sizes per the ES2 I&O manual specifications.
Physical and connections
Shipping weight518 lbShipping weight 518 lb; empty (uncrated) boiler weight 438 lb, per the ES2 I&O manual weights and volume table.
Supply/return connections1-1/4" NPTSupply and return both 1-1/4" NPT; relief valve 3/4" and drain 3/4" per the ES2 I&O manual.
Gas connection3/4" NPT3/4" NPT gas connection (ES27–ES29); ES23–ES26 use 1/2" NPT.
Electrical
Electrical120 VAC, 60 Hz, 1-phase, 15 APer the ES2 I&O manual specifications.
Operating limits and other
Maximum allowable working pressure (MAWP)50 psi50 psi MAWP; the boiler ships from the factory with a 30 psi safety relief valve.
ControlIQ Boiler Control SystemIQ control with optional outdoor-reset and LWCO IQ option cards; the control flashes 'Err' + number for faults.

Frequently asked questions

What are the ES28's ratings?

245 MBH fixed input, 208 MBH DOE heating capacity, a 181 MBH net AHRI water rating and 85% AFUE per the ES2 ratings table.

What are the ES28's dimensions?

The ES28 measures 35" deep, 27-3/4" wide and 41" high per the ES2 I&O manual dimensions and connections table.

Is the ES28 the largest ES2?

No — the ES29 is larger at 280 MBH input; the ES28 is the second-largest size.

Questions about the Burnham ES2 ES28?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate