Burnham ES2 ES28 vs ES29

Verdict in brief

The ES29 is the top of the ES2 cast-iron line: 280 MBH fixed input against the ES28's 245 MBH, for 238 MBH DOE heating capacity (208 on the ES28) and a 207 MBH net AHRI rating (181), moving to the line's largest 8" draft hood and 564 lb shipping weight.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Burnham ES2 ES28 and Burnham ES2 ES29
SpecificationBurnham ES2 ES28Burnham ES2 ES29
Input245 MBH280 MBH
DOE heating capacity208 MBH238 MBH
Net AHRI water rating181 MBH207 MBH
Efficiency (AFUE)85 %85 %
VentingCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 7" draft hoodCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 8" draft hood
Shipping weight518 lb564 lb
Gas connection3/4" NPT3/4" NPT
Supply/return connections1-1/4" NPT1-1/4" NPT
Maximum allowable working pressure (MAWP)50 psi50 psi
Electrical120 VAC, 60 Hz, 1-phase, 15 A120 VAC, 60 Hz, 1-phase, 15 A

What actually separates them

Both are non-condensing cast-iron ES2 boilers at 85% AFUE with fixed inputs, 3/4" NPT gas and 1-1/4" NPT supply/return, on the IQ Boiler Control System at 50 psi MAWP with a 30 psi shipped relief valve.

The ES29 fires a fixed 280 MBH against the ES28's 245 MBH, and the ratings table prints 238 MBH DOE heating capacity and a 207 MBH net AHRI water rating versus 208 and 181 MBH.

The ES29 carries the line's only 8" draft hood (the ES27 and ES28 use 7"), ships at 564 lb (484 lb empty) versus 518 lb (438 lb empty) on the ES28, and at 35" deep by 30-3/4" wide by 41" high is the widest member of the family. Both are Category I chimney-vented designs for large replacement loads.

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Burnham ES2 ES28 fires a fixed 245 MBH input for 208 MBH DOE heating capacity and a 181 MBH net AHRI rating at 85% AFUE, with a 7" draft hood and 3/4" NPT gas — the second-largest non-condensing ES2 cast-iron size.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Burnham ES2 ES29 tops the ES2 cast-iron line at a fixed 280 MBH input: 238 MBH DOE heating capacity and a 207 MBH net AHRI rating at 85% AFUE, with the line's largest 8" draft hood for Category I chimney venting.

Natural gasPropaneHeating-only

Frequently asked questions

What is the largest ES2 boiler?

The ES29: 280 MBH fixed input, 238 MBH DOE heating capacity, a 207 MBH net AHRI water rating and an 8" draft hood — the only ES2 size with that hood.

How do the ES28 and ES29 compare?

The ES29 adds 35 MBH of input (280 vs 245), 30 MBH of DOE capacity (238 vs 208), 26 MBH of net AHRI (207 vs 181) and 46 lb of shipping weight (564 vs 518 lb).

Do both need an 8" chimney connection?

No — the ES28 uses a 7" draft hood; the 8" hood is specific to the ES29.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate