Burnham · Burnham ES2

Burnham ES2 ES29

The Burnham ES2 ES29 tops the ES2 cast-iron line at a fixed 280 MBH input: 238 MBH DOE heating capacity and a 207 MBH net AHRI rating at 85% AFUE, with the line's largest 8" draft hood for Category I chimney venting.

CurrentCanadian status unknown

Key figures

Max input
280 MBH
Max CSA output
AFUE
85 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham ES2 ES29 in practice

The ES29 is the largest ES2 ('Efficiency Series 2') boiler: a fixed 280 MBH input for 238 MBH DOE heating capacity and a 207 MBH net AHRI water rating at 85% AFUE (ES2 I&O ratings table, Doc 103780-11). It is a NON-condensing cast-iron boiler carrying the line's largest 8" natural-draft draft hood, vented Category I into an existing lined chimney — the chimney-replacement design U.S. Boiler markets the ES2 as.

The ES29 ships at 564 lb (484 lb empty) with 1-1/4" NPT supply/return and 3/4" NPT gas, on the IQ Boiler Control System with optional outdoor-reset/LWCO IQ cards, natural or LP gas. MAWP is 50 psi (30 psi relief shipped); supply water runs 130–220°F with a 110°F minimum return, and the family's maximum build measures 35" deep by 30-3/4" wide by 41" high. Ratings apply to 2,000 ft elevation with the manual's Appendix G covering higher sites. Size from a heat-loss calculation; a licensed contractor performs the installation.

Best suited to

  • Large plants whose chimney-vented load approaches a fixed 280 MBH input
  • Replacements needing an 8" draft-hood connector into an existing lined chimney
  • Projects at the top of the non-modulating cast-iron ES2 catalogue

Applicability and support

Model number
ES29
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham ES2 ES29 specifications
SpecificationValueNote
Input
Input280 MBHFixed input (no modulation) per the ES2 ratings table (Doc 103780-11); ratings apply to elevations up to 2,000 ft.
Output
DOE heating capacity238 MBHPer the ES2 ratings table.
Net AHRI water rating207 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15, per the ES2 ratings table.
Efficiency
Efficiency (AFUE)85 %85% AFUE — a NON-condensing rating; the ES2 is a natural-draft cast-iron boiler, not a condensing design.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
VentingCategory I natural draft — draft hood into an existing lined chimney (Type B/L gas vent); 8" draft hoodNon-condensing, natural-draft design: NOT a direct-vent or condensing boiler. Draft hood sizes per the ES2 I&O manual specifications.
Physical and connections
Shipping weight564 lbShipping weight 564 lb; empty (uncrated) boiler weight 484 lb, per the ES2 I&O manual weights and volume table.
Supply/return connections1-1/4" NPTSupply and return both 1-1/4" NPT; relief valve 3/4" and drain 3/4" per the ES2 I&O manual.
Gas connection3/4" NPT3/4" NPT gas connection (ES27–ES29); ES23–ES26 use 1/2" NPT.
Electrical
Electrical120 VAC, 60 Hz, 1-phase, 15 APer the ES2 I&O manual specifications.
Operating limits and other
Maximum allowable working pressure (MAWP)50 psi50 psi MAWP; the boiler ships from the factory with a 30 psi safety relief valve.
ControlIQ Boiler Control SystemIQ control with optional outdoor-reset and LWCO IQ option cards; the control flashes 'Err' + number for faults.

Frequently asked questions

What are the ES29's ratings?

280 MBH fixed input, 238 MBH DOE heating capacity, a 207 MBH net AHRI water rating and 85% AFUE per the ES2 ratings table.

What draft hood does the ES29 use?

An 8" draft hood — the largest in the ES2 line — for Category I natural-draft venting into an existing chimney.

How much does the ES29 weigh?

564 lb shipping weight, 484 lb empty, per the ES2 I&O manual weights and volume table.

Questions about the Burnham ES2 ES29?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.