Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

HTP EFTC-140W vs EFTC-199W

Verdict in brief

The EFTC-199W is the larger EFT Combi Wall: it fires 19,900-199,000 BTU/hr for DHW (against the 140W's 28,000-140,000), delivers 9.9 vs 7.1 GPM at a 35 °F rise, and uses the deeper 19.7 x 37 x 16.8 in cabinet at 120 lb. The 140W prints a slightly lower 95.0% AFUE against 95.1% and runs at a 5:1 turndown versus the 199's 10:1.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP EFTC-140W and HTP EFTC-199W
SpecificationHTP EFTC-140WHTP EFTC-199W
Central-heating input, minimum28 MBH19.9 MBH
Central-heating input, maximum140 MBH140 MBH
DHW input, minimum28 MBH19.9 MBH
DHW input, maximum140 MBH199 MBH
AFUE (page table)95 %95.1 %
DHW flow rate at 35 °F rise7.1 gpm9.9 gpm
DHW flow rate at 45 °F rise5.5 gpm7.7 gpm
DHW flow rate at 77 °F rise3.2 gpm4.8 gpm
Shipping weight110 lb120 lb
Dimensions (W x H x D)17.25" W x 34" H x 15.5" D19.7" W x 37" H x 16.8" D

What actually separates them

The retired wall page prints DHW input of 28,000-140,000 BTU/hr and CH 28,000-140,000 for the EFTC-140W, and DHW 19,000-199,000 with CH 19,000-140,000 for the EFTC-199W; LP-520 prints 19,900-199,000 DHW for the 199.

Hot-water delivery rises from 7.1/5.5/3.2 GPM to 9.9/7.7/4.8 GPM at 35/45/77°F rises, while the cabinet grows from 17.25 x 34 x 15.5 in to 19.7 x 37 x 16.8 in and weight from 110 to 120 lb.

Turndown differs by model: the 140W operates at 5:1 and the 199W at 10:1 per the retired page; the page tables print 95.0% vs 95.1% AFUE.

DiscontinuedCanadian status unknown
Input
28–140 MBH
Output (max)
AFUE
95 %

The HTP EFTC-140W is the wall-hung 140 MBH class combi of the retired EFT Combi line: 28,000 to 140,000 BTU/hr CH input, 28,000 to 140,000 BTU/hr DHW input and 95% printed AFUE, recorded from the official retired EFT Combi table.

Natural gasPropaneCombi
DiscontinuedCanadian status unknown
Input
19.9–140 MBH
Output (max)
AFUE
95.1 %

The HTP EFTC-199W is the wall-hung 199 MBH class combi of the retired EFT Combi line: 19,900 to 140,000 BTU/hr CH input, 19,900 to 199,000 BTU/hr DHW input and 95.1% printed AFUE, recorded from the official retired EFT Combi table.

Natural gasPropaneCombi

Frequently asked questions

How much more hot water does the EFTC-199W deliver?

9.9 GPM at a 35°F rise against 7.1 GPM on the EFTC-140W, per LP-520 Table 4.

Do the two wall combis use the same cabinet?

No — the 140W uses the 17.25 x 34 x 15.5 in cabinet and the 199W the 19.7 x 37 x 16.8 in cabinet.

Which has the higher turndown?

The EFTC-199W at 10:1 against 5:1 for the EFTC-140W, as printed on the retired wall page.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate