The HTP EFTC-199W is the wall-hung 199 MBH class combi of the retired EFT Combi line: 19,900 to 140,000 BTU/hr CH input, 19,900 to 199,000 BTU/hr DHW input and 95.1% printed AFUE, recorded from the official retired EFT Combi table.
Key figures
- Max input
- 140 MBH
- Max CSA output
- —
- AFUE
- 95.1 %
- Min input
- 19.9 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
HTP EFTC-199W in practice
The EFTC-199W is one of the two wall-hung EFT Combi models HTP documents on its retired EFT Combi wall page. The page table prints 19,900-199,000 BTU/hr DHW input, 19,900-140,000 BTU/hr CH input and 95.1% AFUE; the LP-520 technical table adds 120 lb shipping weight, a 19.7" W x 37" H x 16.8" D cabinet, 1.5 gal storage tank + 3.5 gal heat exchanger (5 gal total), DHW flows of 9.9 / 7.7 / 4.8 GPM at 35 / 45 / 77°F rise, CH 1" NPT supply/return, DHW 3/4" NPT and a 3/4" NPT gas connection.
The combi uses a 316L stainless steel fire-tube heat exchanger and a stainless steel indirect storage tank, with the 199k model's 10 to 1 turndown, CH 12-30 psi and DHW 150 psi maximum pressures, 2" (50 ft) or 3" (100 ft) sealed-combustion venting and a 10-year limited residential / five-year limited commercial warranty. The retired wall page notes ENERGY STAR certification and low-NOx emissions.
The EFT Combination Boiler (Wall and Floor) is listed on HTP's discontinued-products index; the retired pages and the LP-520/LP-496 manuals remain for support. Boilers.ca records it with productStatus 'discontinued' and canadianStatus 'unknown'; no official Canadian sales statement was found. Gas and combustion work belongs with a licensed contractor against the model's own manual.
Best suited to
- Identifying a retired EFT Combi already installed
- Retrieving the official LP-520/LP-496 documentation for service planning
- Replacement planning for a wall or floor combi with a known DHW draw
Applicability and support
- Model number
- EFTC-199W
- Canadian availability
- unknown
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by HTP. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Central-heating input, minimum | 19.9 MBH | 19,900 BTU/hr as printed in LP-520 Table 4 and the retired EFT Combi wall page table. |
| Central-heating input, maximum | 140 MBH | 140,000 BTU/hr as printed; the 199 models ship at a 140,000 BTU/hr CH maximum and can be increased to 199,000 with a larger external pump per the manual footnote. |
| Efficiency | ||
| AFUE (page table) | 95.1 % | Printed as 95.1% on the retired EFT Combi wall page table; the LP-520 technical table prints 95%. |
| Domestic hot water | ||
| DHW input, minimum | 19.9 MBH | 19,900 BTU/hr as printed on the retired EFT Combi page table. |
| DHW input, maximum | 199 MBH | 199,000 BTU/hr as printed on the retired EFT Combi page table and in the manual technical table. |
| DHW flow rate at 35 °F rise | 9.9 gpm | As printed in the manual technical table (35°F rise row). |
| DHW flow rate at 45 °F rise | 7.7 gpm | As printed in the manual technical table (45°F rise row). |
| DHW flow rate at 77 °F rise | 4.8 gpm | As printed in the manual technical table (77°F rise row). |
| Venting and air | ||
| Venting | 2" (50 ft) or 3" (100 ft), combined equivalent feet | Sealed-combustion direct vent / power vent; Category IV per the retired pages. |
| Physical and connections | ||
| Shipping weight | 120 lb | As printed in the manual technical table. |
| Dimensions (W x H x D) | 19.7" W x 37" H x 16.8" D | As printed in the manual technical table. |
| Water pressure | CH 12-30 psi; DHW maximum 150 psi | As printed in the manual technical table. |
| Heat exchanger and tank | 316L stainless steel fire tube heat exchanger and stainless steel indirect storage tank | Storage: 1.5 gal storage tank + 3.5 gal heat exchanger (5 gal total). |
| Operating limits and other | ||
| Connections | CH supply/return 1" NPT; DHW inlet/outlet 3/4" NPT; gas 3/4" NPT | As printed in the manual technical table. |
| Control | NGTX-900C / P-920C_CB-HTP | Per the manual technical table. |
| Turndown | 10:1 | Retired wall page: 'The 199k BTU unit has a 10 to 1 turndown ratio while the 140k unit operates at a 5 to 1 turndown ratio.' |
| Warranty | 10-year limited residential / 5-year limited commercial | As printed on the retired EFT Combi page. |
Manuals
- HTP EFT Combi Wall (EFTC-140W/199W) Installation and Operation Manual — LP-520 Rev. 10.8.19LP-520 Rev. 10.8.19 · 2019-10-08
Alerts documented for this model
Frequently asked questions
Is the EFTC-199W a combi boiler?
Yes — the C code denotes the combi, and the official table prints a domestic hot water input range of 19,900 to 199,000 BTU/hr plus 9.9 GPM at a 35°F rise.
What is the AFUE of the EFTC-199W?
The retired page table prints 95.1%; the LP-520 technical table prints 95%.
Is the EFT Combi still sold?
No — HTP's discontinued-products index lists the EFT Combination Boiler (floor and wall) and the retired pages remain for documentation only.
Questions about the HTP EFTC-199W?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- HTP — EFT Combi Wall (retired page, model table) · accessed September 9, 2026
- EFT Combi Wall Installation and Operation Manual, LP-520 · accessed September 9, 2026
- HTP — Discontinued Products index · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.