IBC DC 23-84 vs DC 15-95

Verdict in brief

The DC 23-84 and DC 15-95 are adjacent discontinued DC combis. The 15-95 fires lower (15 vs 23 MBH minimum) and slightly higher (95 vs 84 MBH), adds one point of AFUE (95% vs 94%), allows 3.0 vs 2.6 USgpm of DHW flow, and weighs 97 lb against the 23-84's 85 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC DC 23-84 and IBC DC 15-95
SpecificationIBC DC 23-84IBC DC 15-95
Input, minimum23 MBH15 MBH
Input, maximum84 MBH95 MBH
CSA output, minimum21.2 MBH14.4 MBH
CSA output, maximum74.8 MBH85.5 MBH
Efficiency (AFUE)94 %95 %
DHW input23 – 84 MBH15 – 95 MBH
Max. DHW flow rate2.6 USgpm3 USgpm
Power use at full fire (internal pump)126 W128 W
Weight (empty)85 lb97 lb
Pressure vessel water content0.37 USG / 1.4 L0.37 USG / 1.4 L
Max. operating pressure, space-heating coil43.5 psig43.5 psig
Max. equivalent vent length, 3"120 ft120 ft
Max. equivalent vent length, 2"35 ft35 ft

What actually separates them

Both are wall-hung combination boilers with the same coil ratings (43.5 psig space heating, 150 psig DHW), the same 5–14" w.c. gas supply, the same 12,000 ft altitude approval and the same 120 ft of 3" / 35 ft of 2" venting per side. The 23-84's output range is 21.2–74.8 MBH; the 15-95's is 14.4–85.5 MBH.

The 15-95's lower minimum input and higher maximum output come with a higher AFUE, 95% against the 23-84's 94%. On the DHW side the 15-95 allows 3.0 USgpm maximum flow versus 2.6 USgpm on the 23-84, with the same 0.5 USgpm activation threshold.

Weight and manuals split the pair: the 23-84 is 85 lb (39 kg) and covered by I&O manual 120-183-A-R9, while the 15-95 is 97 lb (44 kg) and covered by 120-183-A-R11. The DC Series is discontinued, so both records exist for identification and service rather than new selection.

IBC Technologies

IBC DC 23-84

DiscontinuedHistorically in Canada
Input
23–84 MBH
Output (max)
74.8 MBH
AFUE
94 %

The IBC DC 23-84 is the smallest discontinued DC combi: 23–84 MBH input, 21.2–74.8 MBH output, 94% AFUE and a 2.6 USgpm maximum DHW flow, with 120 ft of 3" venting per side.

Natural gasPropaneCombi

IBC Technologies

IBC DC 15-95

DiscontinuedHistorically in Canada
Input
15–95 MBH
Output (max)
85.5 MBH
AFUE
95 %

The IBC DC 15-95 is a discontinued DC combi rated 15–95 MBH input and 14.4–85.5 MBH output at 95% AFUE, with a 3.0 USgpm maximum DHW flow and 120 ft of 3" venting per side.

Natural gasPropaneCombi

Frequently asked questions

Which DC model has the lower minimum fire?

The DC 15-95, at 15 MBH (4.4 kW) against the DC 23-84's 23 MBH (6.7 kW).

Do the DC 23-84 and DC 15-95 share a manual?

No. The 23-84 is covered by 120-183-A-R9 and the 15-95 by 120-183-A-R11.

Which has the higher DHW flow?

The DC 15-95, at 3.0 USgpm maximum against 2.6 USgpm on the DC 23-84.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.