IBC Technologies · DC Series (discontinued)
IBC DC 23-84
The IBC DC 23-84 is the smallest discontinued DC combi: 23–84 MBH input, 21.2–74.8 MBH output, 94% AFUE and a 2.6 USgpm maximum DHW flow, with 120 ft of 3" venting per side.
Key figures
- Max input
- 84 MBH
- Max CSA output
- 74.8 MBH
- AFUE
- 94 %
- Min input
- 23 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
IBC DC 23-84 in practice
The DC 23-84 was the entry size of IBC's discontinued DC combi line, rated 23–84 MBH CSA input (6.7–24.9 kW) for 21.2–74.8 MBH output (6.2–21.9 kW) at 94% AFUE. It provided space heating and domestic hot water from separate coils in one wall-hung appliance: the space-heating coil is rated 43.5 psig and the DHW coil 150 psig, with the unit shipped with a 30 psig relief valve.
The 23-84's domestic hot water side is the smallest in the DC range, with a maximum DHW flow of 2.6 USgpm and activation at 0.5 USgpm; DHW temperatures run 104–149°F and space-heating water 50–194°F. It weighs 85 lb (39 kg), draws 126 W at full fire with the internal pump, and holds 0.37 USG (1.4 L) of water.
Venting is 120 equivalent feet in 3" or 35 feet in 2" per side, gas supply is 5–14" w.c., and the unit is approved to 12,000 ft altitude. It is covered by the DC I&O manual 120-183-A-R9; the line is discontinued and documented on IBC's Technical Information Portal.
Best suited to
- Owners identifying or servicing an existing DC 23-84 installation
- Small homes or suites where the DC combi's 74.8 MBH output matches the original load
- Technicians comparing the smallest DC size against the 15-95 and 15-96
Applicability and support
- Model number
- DC 23-84
- Canadian availability
- historical
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 23 MBH | 6.7 kW |
| Input, maximum | 84 MBH | 24.9 kW |
| Output | ||
| CSA output, minimum | 21.2 MBH | 6.2 kW |
| CSA output, maximum | 74.8 MBH | 21.9 kW |
| Efficiency | ||
| Efficiency (AFUE) | 94 % | Per the DC specification table. |
| Domestic hot water | ||
| DHW input | 23 – 84 MBH | 6.7 – 24.9 kW |
| Max. DHW flow rate | 2.6 USgpm | |
| Flow to activate DHW | 0.5 USgpm | |
| Domestic hot water | Integrated DHW coil in a combination boiler | |
| Venting and air | ||
| Max. equivalent vent length, 3" | 120 ft | Each side. |
| Max. equivalent vent length, 2" | 35 ft | Each side. |
| Physical and connections | ||
| Weight (empty) | 85 lb | 39 kg |
| Pressure vessel water content | 0.37 USG / 1.4 L | |
| Electrical | ||
| Power use at full fire (internal pump) | 126 W | 120 V / 60 Hz. |
| Operating limits and other | ||
| Maximum boiler flow rate | 9 USgpm | |
| Minimum boiler flow rate | 2 USgpm | |
| Fuel | Natural gas or propane | The DC/HC specification table notes conversion kits must be ordered separately. |
| Gas supply pressure | 5 – 14 in. w.c. | |
| Ambient temperature | 32 – 122 °F | 0 – 50°C. |
| Space-heating water temperature | 50 – 194 °F | 10 – 90°C. |
| Domestic hot water temperature | 104 – 149 °F | 40 – 65°C. |
| Max. operating pressure, space-heating coil | 43.5 psig | DHW coil rated 150 psig; the unit ships with a 30 psig pressure relief valve. |
| Altitude rating | 12,000 ft | |
Manuals
Alerts documented for this model
Frequently asked questions
Is the DC 23-84 still available?
No. The DC Series is discontinued; IBC keeps the specification table and manuals on its Technical Information Portal for owners and technicians.
How much hot water does the DC 23-84 make?
IBC lists a maximum DHW flow of 2.6 USgpm, with activation at 0.5 USgpm and DHW temperatures of 104–149°F.
Which manual covers the DC 23-84?
The DC 23-84 is listed under I&O manual 120-183-A-R9, which IBC still hosts on the portal.
Questions about the IBC DC 23-84?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- IBC Technical Information Portal — DC series specification table · accessed September 9, 2026
- IBC Technical Information Portal — DC series model list · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.