IBC HC 13-50 vs HC 23-84

Verdict in brief

The HC 13-50 and HC 23-84 are the two smallest HC heating boilers. The 23-84 roughly doubles the input ceiling (84 vs 51 MBH) and output (74.8 vs 45.4 MBH) at the same 94% AFUE, adding 1 lb of weight and keeping the same flows, vessel and venting.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC HC 13-50 and IBC HC 23-84
SpecificationIBC HC 13-50IBC HC 23-84
Input, minimum13.5 MBH23 MBH
Input, maximum51 MBH84 MBH
CSA output, minimum12.4 MBH21.2 MBH
CSA output, maximum45.4 MBH74.8 MBH
Efficiency (AFUE)94 %94 %
Power use at full fire (internal pump)126 W126 W
Weight (empty)84 lb85 lb
Pressure vessel water content0.37 USG / 1.4 L0.37 USG / 1.4 L
Maximum boiler flow rate9 USgpm9 USgpm
Minimum boiler flow rate2 USgpm2 USgpm
Max. operating pressure, space-heating coil43.5 psig43.5 psig
Max. equivalent vent length, 3"120 ft120 ft
Max. equivalent vent length, 2"35 ft35 ft

What actually separates them

Both are heating-only wall-hung boilers with no DHW coil: the 13-50 covers 13.5–51 MBH input (3.95–14.94 kW) and 12.4–45.4 MBH output (3.64–13.3 kW), while the 23-84 covers 23–84 MBH input (6.7–24.9 kW) and 21.2–74.8 MBH output (6.2–21.9 kW). Both are rated 94% AFUE.

The published common rows are identical: 43.5 psig maximum space-heating pressure with a supplied 30 psig relief valve, 5–14" w.c. gas, 50–194°F water, 12,000 ft altitude, 120 ft of 3" / 35 ft of 2" venting per side, 9 USgpm maximum and 2 USgpm minimum flow, and 0.37 USG (1.4 L) of vessel water.

The only physical difference is weight — 84 lb (38 kg) on the 13-50 versus 85 lb (39 kg) on the 23-84 — and the power draw, 126 W at full fire on both. Manuals differ: 120-185-A-R10 for the 13-50, 120-185-A-R9 for the 23-84. Both are discontinued.

IBC Technologies

IBC HC 13-50

DiscontinuedHistorically in Canada
Input
13.5–51 MBH
Output (max)
45.4 MBH
AFUE
94 %

The IBC HC 13-50 is the smallest HC Series heating boiler: 13.5–51 MBH input, 12.4–45.4 MBH output at 94% AFUE, 84 lb, and 120 ft of 3" venting per side. It is heating-only.

Natural gasPropaneHeating-only

IBC Technologies

IBC HC 23-84

DiscontinuedHistorically in Canada
Input
23–84 MBH
Output (max)
74.8 MBH
AFUE
94 %

The IBC HC 23-84 is a discontinued heating-only boiler rated 23–84 MBH input and 21.2–74.8 MBH output at 94% AFUE, sharing the DC 23-84's ratings on the heating side without the DHW coil.

Natural gasPropaneHeating-only

Frequently asked questions

Which HC model fires lower?

The HC 13-50, from 13.5 MBH (3.95 kW); the HC 23-84 starts at 23 MBH (6.7 kW).

Do the HC 13-50 and HC 23-84 share a manual?

No. The 13-50 is covered by 120-185-A-R10 and the 23-84 by 120-185-A-R9.

Are their flow requirements the same?

Yes: 9 USgpm maximum and 2 USgpm minimum on both, per the HC specification table.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.