IBC HC 15-96 vs HC 29-106

Verdict in brief

The HC 29-106 adds about 8.4 MBH of output over the HC 15-96 but gives up two points of AFUE (94% vs 96%), raises the minimum fire from 15 to 28.5 MBH, and is lighter at 85 lb versus 96 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC HC 15-96 and IBC HC 29-106
SpecificationIBC HC 15-96IBC HC 29-106
Input, minimum15 MBH28.5 MBH
Input, maximum96 MBH106 MBH
CSA output, minimum14.5 MBH26.3 MBH
CSA output, maximum85.9 MBH94.3 MBH
Efficiency (AFUE)96 %94 %
Power use at full fire (internal pump)128 W128 W
Weight (empty)96 lb85 lb
Pressure vessel water content0.5 USG / 1.9 L0.37 USG / 1.4 L
Maximum boiler flow rate10 USgpm10 USgpm
Minimum boiler flow rate2 USgpm3 USgpm
Max. operating pressure, space-heating coil43.5 psig43.5 psig
Max. equivalent vent length, 3"120 ft120 ft
Max. equivalent vent length, 2"35 ft35 ft

What actually separates them

The 29-106 covers 28.5–106 MBH input and 26.3–94.3 MBH output; the 15-96 covers 15–96 MBH input and 14.5–85.9 MBH output. The output gap is modest, while the minimum-fire gap is large: 28.5 MBH versus 15 MBH.

Efficiency clearly favours the 15-96 at 96% AFUE against the 29-106's 94%. The 29-106 also carries the HC table's 7.7–27.6 kW output figure, while the DC table prints 8.9–32.3 kW for the same range — Boilers.ca uses the HC page value here.

The 29-106 is lighter at 85 lb (39 kg) versus 96 lb (44 kg) and holds the smaller 0.37 USG (1.4 L) vessel; maximum boiler flow is 10 USgpm on both, but the minimum rises from 2 to 3 USgpm. Manuals differ: 120-185-A-R10 for the 15-96 and 120-185-A-R9 for the 29-106.

IBC Technologies

IBC HC 15-96

DiscontinuedHistorically in Canada
Input
15–96 MBH
Output (max)
85.9 MBH
AFUE
96 %

The IBC HC 15-96 is the highest-efficiency HC boiler at 96% AFUE, rated 15–96 MBH input and 14.5–85.9 MBH output, with 0.5 USG of vessel water and 120 ft of 3" venting per side.

Natural gasPropaneHeating-only

IBC Technologies

IBC HC 29-106

DiscontinuedHistorically in Canada
Input
28.5–106 MBH
Output (max)
94.3 MBH
AFUE
94 %

The IBC HC 29-106 is a discontinued heating-only boiler rated 28.5–106 MBH input and 26.3–94.3 MBH output at 94% AFUE, with the HC table's 7.7–27.6 kW output figure.

Natural gasPropaneHeating-only

Frequently asked questions

Which HC model is more efficient?

The HC 15-96 at 96% AFUE; the HC 29-106 is rated 94%.

Why does the HC 29-106 output kW differ from the DC 29-106?

IBC's HC table prints 7.7–27.6 kW for the 29-106 output range while the DC table prints 8.9–32.3 kW. Boilers.ca records each page as printed.

Which manual covers the HC 29-106?

HC I&O manual 120-185-A-R9; the 15-96 uses 120-185-A-R10.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.