IBC HC 23-84 vs HC 15-95

Verdict in brief

The HC 15-95 edges out the HC 23-84 with 85.5 MBH output against 74.8, a lower 15 MBH minimum fire, 95% AFUE against 94%, and a 10 USgpm maximum flow against 9. It weighs 91 lb versus 85 lb and uses a different manual.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC HC 23-84 and IBC HC 15-95
SpecificationIBC HC 23-84IBC HC 15-95
Input, minimum23 MBH15 MBH
Input, maximum84 MBH95 MBH
CSA output, minimum21.2 MBH14.4 MBH
CSA output, maximum74.8 MBH85.5 MBH
Efficiency (AFUE)94 %95 %
Power use at full fire (internal pump)126 W128 W
Weight (empty)85 lb91 lb
Pressure vessel water content0.37 USG / 1.4 L0.37 USG / 1.4 L
Maximum boiler flow rate9 USgpm10 USgpm
Minimum boiler flow rate2 USgpm2 USgpm
Max. operating pressure, space-heating coil43.5 psig43.5 psig
Max. equivalent vent length, 3"120 ft120 ft
Max. equivalent vent length, 2"35 ft35 ft

What actually separates them

The HC 23-84 covers 23–84 MBH input and 21.2–74.8 MBH output; the HC 15-95 covers 15–95 MBH input and 14.4–85.5 MBH output. The 15-95's lower minimum fire and higher maximum output make it the more flexible of the two across a range of loads.

Efficiency also favours the 15-95 at 95% AFUE versus 94%, and its maximum boiler flow is 10 USgpm against 9, though both keep a 2 USgpm minimum and the same 0.37 USG (1.4 L) vessel. Weight rises modestly to 91 lb (41 kg) from 85 lb (39 kg), and full-fire power draw is 128 W versus 126 W.

Everything else matches: 43.5 psig space-heating coil, supplied 30 psig relief valve, 5–14" w.c. gas, 50–194°F water, 12,000 ft altitude and 120 ft of 3" / 35 ft of 2" venting per side. The 23-84 uses manual 120-185-A-R9 and the 15-95 uses 120-185-A-R10.

IBC Technologies

IBC HC 23-84

DiscontinuedHistorically in Canada
Input
23–84 MBH
Output (max)
74.8 MBH
AFUE
94 %

The IBC HC 23-84 is a discontinued heating-only boiler rated 23–84 MBH input and 21.2–74.8 MBH output at 94% AFUE, sharing the DC 23-84's ratings on the heating side without the DHW coil.

Natural gasPropaneHeating-only

IBC Technologies

IBC HC 15-95

DiscontinuedHistorically in Canada
Input
15–95 MBH
Output (max)
85.5 MBH
AFUE
95 %

The IBC HC 15-95 is a discontinued heating-only boiler rated 15–95 MBH input and 14.4–85.5 MBH output at 95% AFUE, weighing 91 lb with 120 ft of 3" venting per side.

Natural gasPropaneHeating-only

Frequently asked questions

Which HC model has the higher AFUE?

The HC 15-95 at 95%, against 94% on the HC 23-84.

How much more output does the HC 15-95 have?

About 10.7 MBH at the top end: 85.5 MBH versus 74.8 MBH.

Which manual covers each?

HC 23-84: 120-185-A-R9; HC 15-95: 120-185-A-R10.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate