Skip to content
Boilers.caby ROMA Heating & Cooling

IBC Technologies · HC Series (discontinued)

IBC HC 15-95

The IBC HC 15-95 is a discontinued heating-only boiler rated 15–95 MBH input and 14.4–85.5 MBH output at 95% AFUE, weighing 91 lb with 120 ft of 3" venting per side.

DiscontinuedHistorically in Canada

Key figures

Max input
95 MBH
Max CSA output
85.5 MBH
AFUE
95 %
Min input
15 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

IBC HC 15-95 in practice

The HC 15-95 covers 15–95 MBH CSA input (4.4–27.8 kW) for 14.4–85.5 MBH output (4.2–25.0 kW) at 95% AFUE. It shares its heating-side ratings with the DC 15-95 combi but has no domestic-hot-water coil, so its specification rows stop at the 43.5 psig space-heating coil and 50–194°F water temperatures.

The unit weighs 91 lb (41 kg) — between the 23-84's 85 lb and the 15-96's 96 lb — holds 0.37 USG (1.4 L) and draws 128 W at full fire with the internal pump. Maximum boiler flow is 10 USgpm and the minimum is 2 USgpm; gas supply is 5–14" w.c. and the altitude rating is 12,000 ft.

The 15-95 is covered by HC I&O manual 120-185-A-R10. Venting is 120 equivalent feet in 3" or 35 feet in 2" per side, and the discontinued HC Series remains documented on IBC's Technical Information Portal.

Best suited to

  • Owners documenting an HC 15-95 installation against the HC spec table
  • Homes where 85.5 MBH output matches the heat loss and DHW is separate
  • Technicians comparing the HC 15-95 with the 15-96

Applicability and support

Model number
HC 15-95
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.

IBC HC 15-95 specifications
SpecificationValueNote
Input
Input, minimum15 MBH4.4 kW
Input, maximum95 MBH27.8 kW
Output
CSA output, minimum14.4 MBH4.2 kW
CSA output, maximum85.5 MBH25.0 kW
Efficiency
Efficiency (AFUE)95 %Per the HC specification table.
Domestic hot water
Domestic hot waterHeating-only boiler; no DHW coil
Venting and air
Max. equivalent vent length, 3"120 ftEach side.
Max. equivalent vent length, 2"35 ftEach side.
Physical and connections
Weight (empty)91 lb41 kg
Pressure vessel water content0.37 USG / 1.4 L
Electrical
Power use at full fire (internal pump)128 W120 V / 60 Hz.
Operating limits and other
Maximum boiler flow rate10 USgpm
Minimum boiler flow rate2 USgpm
FuelNatural gas or propaneThe DC/HC specification table notes conversion kits must be ordered separately.
Gas supply pressure5 – 14 in. w.c.
Ambient temperature32 – 122 °F0 – 50°C.
Space-heating water temperature50 – 194 °F10 – 90°C.
Max. operating pressure, space-heating coil43.5 psigThe unit ships with a 30 psig pressure relief valve.
Altitude rating12,000 ft

Frequently asked questions

Does the HC 15-95 have a DHW coil?

No. The HC Series is heating-only; the DC Series provided the combination-boiler version.

What is the HC 15-95's AFUE?

95%, per the HC specification table.

Which manual covers the HC 15-95?

HC I&O manual 120-185-A-R10 lists the HC 15-95 among the models it covers.

Questions about the IBC HC 15-95?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate