Comparison

IBC HC 29-106 vs HC 20-125

Verdict in brief

The HC 20-125 fires down to 20 MBH instead of 28.5, reaches 110.8 MBH output instead of 94.3, and is rated 95% AFUE against the HC 29-106's 94%. It weighs 96 lb versus 85 lb and holds a larger 0.5 USG vessel.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC HC 29-106 and IBC HC 20-125
SpecificationIBC HC 29-106IBC HC 20-125
Input, minimum28.5 MBH20 MBH
Input, maximum106 MBH125 MBH
CSA output, minimum26.3 MBH18.6 MBH
CSA output, maximum94.3 MBH110.8 MBH
Efficiency (AFUE)94 %95 %
Power use at full fire (internal pump)128 W130 W
Weight (empty)85 lb96 lb
Pressure vessel water content0.37 USG / 1.4 L0.5 USG / 1.9 L
Maximum boiler flow rate10 USgpm11 USgpm
Minimum boiler flow rate3 USgpm3 USgpm
Max. operating pressure, space-heating coil43.5 psig43.5 psig
Max. equivalent vent length, 3"120 ft120 ft
Max. equivalent vent length, 2"35 ft35 ft

What actually separates them

The 20-125 covers 20–125 MBH input and 18.6–110.8 MBH output; the 29-106 covers 28.5–106 MBH input and 26.3–94.3 MBH output. Both the low end and the top end favour the 20-125, and its AFUE is one point higher at 95% against 94%.

The 20-125 also carries the larger 0.5 USG (1.9 L) vessel and an 11 USgpm maximum flow against 10 USgpm, while both keep a 3 USgpm minimum. Full-fire power is 130 W versus 128 W, and weight is 96 lb (44 kg) versus 85 lb (39 kg).

All other rows match: 43.5 psig space-heating coil, supplied 30 psig relief valve, 5–14" w.c. gas, 50–194°F water, 12,000 ft altitude and 120 ft of 3" / 35 ft of 2" venting per side. The 29-106 uses manual 120-185-A-R9 and the 20-125 appears in both 120-185-A-R10 and 120-185-A-R9.

IBC Technologies

IBC HC 29-106

DiscontinuedHistorically in Canada
Input
28.5–106 MBH
Output (max)
94.3 MBH
AFUE
94 %

The IBC HC 29-106 is a discontinued heating-only boiler rated 28.5–106 MBH input and 26.3–94.3 MBH output at 94% AFUE, with the HC table's 7.7–27.6 kW output figure.

Natural gasPropaneHeating-only

IBC Technologies

IBC HC 20-125

DiscontinuedHistorically in Canada
Input
20–125 MBH
Output (max)
110.8 MBH
AFUE
95 %

The IBC HC 20-125 is a discontinued heating-only boiler rated 20–125 MBH input and 18.6–110.8 MBH output at 95% AFUE, with a 20 MBH minimum fire and 0.5 USG of vessel water.

Natural gasPropaneHeating-only

Frequently asked questions

Which HC model fires lower?

The HC 20-125, from 20 MBH (5.6 kW) against the HC 29-106's 28.5 MBH (8.4 kW).

Which has higher output?

The HC 20-125 at 110.8 MBH CSA output versus 94.3 MBH on the HC 29-106.

Is the HC 20-125 in both HC manuals?

Yes. Both 120-185-A-R10 and 120-185-A-R9 list the HC 20-125.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.