Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

IBC SFC 125-1 vs SFC 199-1

Verdict in brief

The SFC 125-1 and SFC 199-1 are the two largest SFC combis: the 199-1 lifts space heating to 125 MBH input (111 MBH CSA output) and DHW to 199 MBH with 5 GPM continuous delivery and a 7 GPM peak, adds a built-in DHW bypass valve and wireless cascade, and weighs 1 lb less than the 125-1.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC SFC 125-1 Superflow and IBC SFC 199-1 Superflow
SpecificationIBC SFC 125-1 SuperflowIBC SFC 199-1 Superflow
Heating input, minimum16.5 MBH28.5 MBH
Heating input, maximum99 MBH125 MBH
DHW input, maximum125 MBH199 MBH
CSA output, maximum89 MBH111 MBH
Efficiency (AFUE)95 %95 %
Weight (empty)85 lb84 lb
Max. equivalent vent length, 2"65 ft65 ft
Max. equivalent vent length, 3"120 ft120 ft
Max. DHW flow rate4 GPM7 GPM
Gas connection3/4" NPT3/4" NPT

What actually separates them

Unlike the step from the 99 to the 125, moving to the SFC 199-1 raises both sides of the appliance: space-heating input goes from 99 to 125 MBH (CSA output from 89 to 111 MBH) and DHW input from 125 to 199 MBH.

The DHW gains are the headline: continuous delivery rises from 3.2 to 5.0 GPM (67°F rise) and maximum DHW flow from 4 to 7 GPM. The 199-1 also carries the built-in bypass valve that steadies DHW temperature and supports wireless cascading of up to eight units.

Both models weigh about the same (85 vs 84 lb) and share the 2" (65 ft) and 3" (120 ft) venting and 95% AFUE rating. The 199-1's higher DHW input means the gas supply and venting must support firing to 199 MBH during hot-water draws.

IBC Technologies

IBC SFC 125-1 Superflow

CurrentSold in Canada
Input
16.5–99 MBH
Output (max)
89 MBH
AFUE
95 %

The IBC SFC 125-1 Superflow is a wall-hung condensing combi boiler rated 95% AFUE: up to 99 MBH for space heating and 125 MBH for domestic hot water, with 3.2 GPM continuous DHW delivery at a 67°F rise.

Natural gasPropaneCombi

IBC Technologies

IBC SFC 199-1 Superflow

CurrentSold in Canada
Input
28.5–125 MBH
Output (max)
111 MBH
AFUE
95 %

The IBC SFC 199-1 is the largest Superflow combi: 95% AFUE, up to 125 MBH for space heating and 199 MBH for hot water, 5 GPM continuous DHW at a 67°F rise, with wireless cascade of up to eight units on the SFC 199-1.

Natural gasPropaneCombi

Frequently asked questions

What does the SFC 199-1 add over the 125-1?

Heating input rises from 99 to 125 MBH, DHW delivery from 3.2 to 5.0 GPM continuous, peak DHW flow from 4 to 7 GPM, plus a built-in bypass valve and wireless cascade capability.

Do I need a bigger gas line for the 199-1?

The 199-1 can fire to 199 MBH during DHW draws, so the gas supply must be sized for that input. A technician confirms this during the assessment.

Are both models 95% AFUE?

Yes. The SFC 125-1 and SFC 199-1 are both rated 95% AFUE by IBC; the smaller SFC 99-1 is rated 96%.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate