Skip to content
Boilers.caby ROMA Heating & Cooling

IBC Technologies · Superflow SFC-1 Combi

IBC SFC 199-1 Superflow

The IBC SFC 199-1 is the largest Superflow combi: 95% AFUE, up to 125 MBH for space heating and 199 MBH for hot water, 5 GPM continuous DHW at a 67°F rise, with wireless cascade of up to eight units on the SFC 199-1.

CurrentSold in Canada

Key figures

Max input
125 MBH
Max CSA output
111 MBH
AFUE
95 %
Min input
28.5 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

IBC SFC 199-1 Superflow in practice

The SFC 199-1 delivers the highest DHW capacity in the SFC line: 199 MBH of input for hot water, 5 GPM continuous delivery at a 67°F rise, and up to 7 GPM peak DHW flow. Its space-heating side is capped at 125 MBH input, which keeps the appliance matched to homes that need modest heat but generous hot water.

A built-in bypass valve stabilizes DHW temperature when a hot-water draw starts or stops, and the model supports wireless cascading of up to eight units for larger multi-suite applications, with both space-heating and DHW cascade configurations documented by IBC.

The heat exchanger condenses during heating and hot-water operation, so condensate handling and direct-vent installation in 2" or 3" PVC, CPVC or PPs apply as with the rest of the SFC line. Fault codes are numeric (F-series) on the touch panel and are documented on this site against the manual version.

Best suited to

  • Homes and small buildings with high simultaneous hot-water demand
  • Strata or multi-suite projects where one SFC-1 (or a wireless cascade) supplies a plant room
  • Households that want combi convenience with the largest DHW reserve in IBC's wall-hung line

Applicability and support

Model number
SFC 199-1
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.

IBC SFC 199-1 Superflow specifications
SpecificationValueNote
Input
Heating input, minimum28.5 MBH8.4 kW
Heating input, maximum125 MBH36.6 kW. Space heating is capped below the DHW input on this model.
Output
CSA output, minimum27.1 MBH7.9 kW
CSA output, maximum111 MBH32.5 kW. DOE heating capacity is not published on the IBC pages we cite.
Efficiency
Efficiency (AFUE)95 %As published by IBC on the Canadian model page.
Domestic hot water
DHW input, maximum199 MBH58.3 kW
DHW delivery at 67°F rise5 GPMContinuous delivery per IBC Canada model page; the SFC 99-1 page uses a 70°F-rise figure instead.
Max. DHW flow rate7 GPM
Flow to activate DHW0.5 GPM
Domestic hot waterIntegrated coil in the main heat exchanger (combi); built-in bypass valve to steady DHW temperatures
Venting and air
Flue material2" Schedule 40 PVC, CPVC or PPsCanada: venting must meet ULC S636 where applicable.
Max. equivalent vent length, 2"65 ftEach side.
Max. equivalent vent length, 3"120 ftEach side.
Physical and connections
Weight (empty)84 lb38 kg
Heating water connections1" NPT
DHW connections3/4" NPT
Gas connection3/4" NPT
Condensate connection3/4" hose
Operating limits and other
FuelNatural gas or propaneConversion kit included per IBC model page.
Gas supply pressure4 – 14 in. w.c.
Max. operating pressure, heating coil43.5 psigDHW coil rated 150 psig.
Altitude rating10,000 ftPer IBC Canada model page and installation manual.

Frequently asked questions

How much hot water can the SFC 199-1 deliver?

5 GPM continuously at a 67°F temperature rise per IBC's Canadian model page, with a maximum DHW flow of 7 GPM.

Can the SFC 199-1 heat a large house?

Its space-heating input is capped at 125 MBH (up to 111 MBH CSA output), so it suits homes whose calculated heat loss fits that range; the 199 MBH figure applies to the DHW side.

Does the SFC 199-1 support cascading?

Yes. IBC documents wireless cascade of up to eight SFC units on the 199 model, including cascade configurations for domestic hot water.

Questions about the IBC SFC 199-1 Superflow?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate