IBC SFC 99-1 Superflow vs NTI Trinity FTVN110C

Verdict in brief

The IBC SFC 99-1 and NTI Trinity FTVN110C are both compact wall-hung combis near the 99-110 MBH heating mark at 95-96% AFUE, but their DHW and heating balances differ: IBC caps heating at 99 MBH with 2.4 GPM continuous DHW at a 70°F rise, while NTI heats 11 to 110 MBH with 2.7 GPM at a 77°F rise. The heat-loss calculation sizes the heating side; the DHW rating checks showers.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC SFC 99-1 Superflow and NTI Trinity FTVN110C
SpecificationIBC SFC 99-1 SuperflowNTI Trinity FTVN110C
Heating input, minimum15.5 MBH11 MBH
Heating input, maximum99 MBH110 MBH
Efficiency (AFUE)96 %95 %
FuelNatural gas or propaneNatural gas or propane
Weight (empty)85 lb107 lb
Max. equivalent vent length, 2"65 ft100 ft
Max. equivalent vent length, 3"120 ft150 ft
Heating water connections1" NPT1 1/4" NPT
DHW connections3/4" NPT3/4" NPT
Gas connection3/4" NPT3/4" NPT
Domestic hot waterIntegrated coil in the main heat exchanger (combi)Integrated combi (DHW plate) in the appliance

What actually separates them

Both are wall-hung combis that produce domestic hot water in the appliance, and both list natural gas or propane with a conversion kit. IBC rates the SFC 99-1 at 96% AFUE and caps its heating input at 99 MBH (29.0 kW), while NTI lists the FTVN110C at 95% AFUE with an 11 to 110 MBH heating range — about 11 MBH more heating headroom and a lower 11 MBH minimum fire on the NTI side.

Hot water is where the two philosophies show: IBC publishes 2.4 GPM continuous DHW delivery at a 70°F rise for the SFC 99-1 with a 4 GPM maximum DHW flow, while NTI publishes 2.7 GPM continuous at a 77°F rise for the FTVN110C. Both figures are continuous ratings at stated rises, so the practical test is whether simultaneous bathroom draws stay under the published flow at the home's incoming water temperature.

Installation packages are close: the SFC 99-1 weighs 85 lb (39 kg) with 1" heating and 3/4" DHW and gas connections, and vents 2" to 65 feet or 3" to 120 feet per side; the FTVN110C weighs 107 lb with 1 1/4" heating connections and vents 2" to 100 feet or 3" to 150 feet per side. Sizing starts from a heat-loss calculation plus the household's hot-water draw pattern.

IBC Technologies

IBC SFC 99-1 Superflow

CurrentSold in Canada
Input
15.5–99 MBH
Output (max)
89 MBH
AFUE
96 %

The IBC SFC 99-1 is the smallest Superflow SFC combi boiler: up to 99 MBH input for space heating and DHW, 96% AFUE, wall-hung, with 2" or 3" PVC/CPVC/PPs venting. It is a fit for townhouses and smaller homes wanting one appliance for heat and hot water.

Natural gasPropaneCombi
CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The NTI Trinity FTVN110C is the smallest FTVN combi: it heats at 11 to 110 MBH input and delivers 2.7 GPM of continuous domestic hot water at a 77°F rise, all in the same 107 lb wall-hung cabinet as the heating-only FTVN110.

Natural gasPropaneCombi

Frequently asked questions

Which combi delivers more continuous hot water?

NTI publishes 2.7 GPM continuous at a 77°F rise for the FTVN110C versus 2.4 GPM at a 70°F rise for the IBC SFC 99-1, though each rating uses a different temperature-rise basis.

Do both boilers heat the same size home?

Close, but not identical: the FTVN110C heats to 110 MBH input while the SFC 99-1 is capped at 99 MBH, so a heat-loss calculation decides which ceiling the home needs.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate