IBC Technologies · Superflow SFC-1 Combi
IBC SFC 99-1 Superflow
The IBC SFC 99-1 is the smallest Superflow SFC combi boiler: up to 99 MBH input for space heating and DHW, 96% AFUE, wall-hung, with 2" or 3" PVC/CPVC/PPs venting. It is a fit for townhouses and smaller homes wanting one appliance for heat and hot water.
Key figures
- Max input
- 99 MBH
- Max CSA output
- 89 MBH
- AFUE
- 96 %
- Min input
- 15.5 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
IBC SFC 99-1 Superflow in practice
The SFC 99-1 condenses flue gases while making hot water as well as heat, because both the central-heating coil and the DHW coil live in the same cast-aluminium heat exchanger. IBC's Canadian page rates this model at 96% AFUE, the highest figure in the SFC line.
Its 15.5 to 99 MBH input range and 2.4 GPM continuous DHW delivery at a 70°F rise suit compact homes and townhouses with modest simultaneous hot-water demand. The built-in variable-speed pump, bypass control and numeric-display controller keep the near-boiler package small, which matters in tight utility closets.
Venting is 2" or 3" Schedule 40 PVC, CPVC or PPs to 65 or 120 equivalent feet per side respectively, and the unit is direct-vent only. Because the appliance condenses in DHW mode too, the condensate drain must be functional year-round, not only in heating season.
Best suited to
- Townhouses, suites and compact detached homes with modest hot-water demand
- Homes where one wall-hung appliance must replace both boiler and tank
- Replacement jobs where the existing 2" vent route can be reused within limits
Applicability and support
- Model number
- SFC 99-1
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 15.5 MBH | 4.54 kW |
| Heating input, maximum | 99 MBH | 29.0 kW |
| Output | ||
| CSA output, minimum | 14.8 MBH | 4.34 kW |
| CSA output, maximum | 89 MBH | 26.1 kW. DOE heating capacity is not published on the IBC pages we cite. |
| Efficiency | ||
| Efficiency (AFUE) | 96 % | 96% AFUE per IBC Canada model page; the larger SFC models are rated 95%. |
| Domestic hot water | ||
| DHW input, maximum | 99 MBH | 29.0 kW. Equal to the heating input on this model. |
| DHW delivery at 70°F rise | 2.4 GPM | Continuous delivery per IBC Canada model page. |
| Max. DHW flow rate | 4 GPM | |
| Flow to activate DHW | 0.5 GPM | |
| Domestic hot water | Integrated coil in the main heat exchanger (combi) | |
| Venting and air | ||
| Flue material | 2" Schedule 40 PVC, CPVC or PPs | Canada: venting must meet ULC S636 where applicable. |
| Max. equivalent vent length, 2" | 65 ft | Each side. |
| Max. equivalent vent length, 3" | 120 ft | Each side. |
| Physical and connections | ||
| Weight (empty) | 85 lb | 39 kg |
| Heating water connections | 1" NPT | |
| DHW connections | 3/4" NPT | |
| Gas connection | 3/4" NPT | |
| Condensate connection | 3/4" hose | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Conversion kit included per IBC model page. |
| Gas supply pressure | 4 – 14 in. w.c. | |
| Max. operating pressure, heating coil | 43.5 psig | DHW coil rated 150 psig. |
| Altitude rating | 10,000 ft | Per IBC Canada model page and installation manual. |
Manuals
Alerts documented for this model
Frequently asked questions
Does the SFC 99-1 make enough hot water for two bathrooms?
It delivers 2.4 GPM continuously at a 70°F rise per IBC's Canadian page. Whether that covers two simultaneous showers depends on the incoming water temperature and the fixtures; the SFC 125-1 and SFC 199-1 deliver more.
Can the SFC 99-1 run on propane?
Yes. IBC lists natural gas or propane with a fuel conversion kit included.
What does the SFC 99-1 weigh?
85 lb (39 kg) empty, per IBC's Canadian model page.
Questions about the IBC SFC 99-1 Superflow?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- IBC SFC 99-1 — model page (Canada) · accessed September 7, 2026
- IBC SUPERFLOW SFC-1 — series page (Canada) · accessed September 7, 2026
- IBC SFC-1 Installation & Operating Instructions · 84156406 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.