Skip to content
Boilers.caby ROMA Heating & Cooling

IBC Technologies · Superflow SFC-1 Combi

IBC SFC 99-1 Superflow

The IBC SFC 99-1 is the smallest Superflow SFC combi boiler: up to 99 MBH input for space heating and DHW, 96% AFUE, wall-hung, with 2" or 3" PVC/CPVC/PPs venting. It is a fit for townhouses and smaller homes wanting one appliance for heat and hot water.

CurrentSold in Canada

Key figures

Max input
99 MBH
Max CSA output
89 MBH
AFUE
96 %
Min input
15.5 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

IBC SFC 99-1 Superflow in practice

The SFC 99-1 condenses flue gases while making hot water as well as heat, because both the central-heating coil and the DHW coil live in the same cast-aluminium heat exchanger. IBC's Canadian page rates this model at 96% AFUE, the highest figure in the SFC line.

Its 15.5 to 99 MBH input range and 2.4 GPM continuous DHW delivery at a 70°F rise suit compact homes and townhouses with modest simultaneous hot-water demand. The built-in variable-speed pump, bypass control and numeric-display controller keep the near-boiler package small, which matters in tight utility closets.

Venting is 2" or 3" Schedule 40 PVC, CPVC or PPs to 65 or 120 equivalent feet per side respectively, and the unit is direct-vent only. Because the appliance condenses in DHW mode too, the condensate drain must be functional year-round, not only in heating season.

Best suited to

  • Townhouses, suites and compact detached homes with modest hot-water demand
  • Homes where one wall-hung appliance must replace both boiler and tank
  • Replacement jobs where the existing 2" vent route can be reused within limits

Applicability and support

Model number
SFC 99-1
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.

IBC SFC 99-1 Superflow specifications
SpecificationValueNote
Input
Heating input, minimum15.5 MBH4.54 kW
Heating input, maximum99 MBH29.0 kW
Output
CSA output, minimum14.8 MBH4.34 kW
CSA output, maximum89 MBH26.1 kW. DOE heating capacity is not published on the IBC pages we cite.
Efficiency
Efficiency (AFUE)96 %96% AFUE per IBC Canada model page; the larger SFC models are rated 95%.
Domestic hot water
DHW input, maximum99 MBH29.0 kW. Equal to the heating input on this model.
DHW delivery at 70°F rise2.4 GPMContinuous delivery per IBC Canada model page.
Max. DHW flow rate4 GPM
Flow to activate DHW0.5 GPM
Domestic hot waterIntegrated coil in the main heat exchanger (combi)
Venting and air
Flue material2" Schedule 40 PVC, CPVC or PPsCanada: venting must meet ULC S636 where applicable.
Max. equivalent vent length, 2"65 ftEach side.
Max. equivalent vent length, 3"120 ftEach side.
Physical and connections
Weight (empty)85 lb39 kg
Heating water connections1" NPT
DHW connections3/4" NPT
Gas connection3/4" NPT
Condensate connection3/4" hose
Operating limits and other
FuelNatural gas or propaneConversion kit included per IBC model page.
Gas supply pressure4 – 14 in. w.c.
Max. operating pressure, heating coil43.5 psigDHW coil rated 150 psig.
Altitude rating10,000 ftPer IBC Canada model page and installation manual.

Frequently asked questions

Does the SFC 99-1 make enough hot water for two bathrooms?

It delivers 2.4 GPM continuously at a 70°F rise per IBC's Canadian page. Whether that covers two simultaneous showers depends on the incoming water temperature and the fixtures; the SFC 125-1 and SFC 199-1 deliver more.

Can the SFC 99-1 run on propane?

Yes. IBC lists natural gas or propane with a fuel conversion kit included.

What does the SFC 99-1 weigh?

85 lb (39 kg) empty, per IBC's Canadian model page.

Questions about the IBC SFC 99-1 Superflow?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate