NTI Trinity FTVN110C
The NTI Trinity FTVN110C is the smallest FTVN combi: it heats at 11 to 110 MBH input and delivers 2.7 GPM of continuous domestic hot water at a 77°F rise, all in the same 107 lb wall-hung cabinet as the heating-only FTVN110.
Key figures
- Max input
- 110 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 11 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI Trinity FTVN110C in practice
The FTVN110C covers space heating and domestic hot water in one appliance, with an integrated DHW plate and diverter inside the boiler and the same 11 to 110 MBH heating input as the FTVN110. NTI rates its continuous DHW capacity at 2.7 GPM for a 77°F temperature rise, which is the figure that decides whether it fits a household's simultaneous shower and tap loads.
For a compact BC home or townhouse the appeal is one wall-hung appliance instead of boiler plus tank. The trade-offs are the DHW ceiling — 2.7 GPM at a 77°F rise is steady single-shower territory, with incoming winter water temperatures lowering real-world delivery — and the 95% AFUE rating, which matches the heating-only FTVN110. When two bathrooms draw at once, the FTVN150C or a heating-only boiler with an indirect tank is the usual next step.
Best suited to
- Townhouses and compact detached homes with one primary bathroom
- Households replacing both boiler and tank with a single wall-hung appliance
- Low heat-loss homes whose heating load fits within 110 MBH and DHW draws stay under 2.7 GPM continuous
Applicability and support
- Model number
- FTVN110C
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Space-heating input, minimum | 11 MBH | Per the NTI product page. |
| Space-heating input, maximum | 110 MBH | Per the NTI product page. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | DOE AFUE per the NTI product page. |
| Domestic hot water | ||
| DHW capacity at 77°F rise | 2.7 GPM | Continuous delivery per the NTI product page. |
| Domestic hot water | Integrated combi (DHW plate) in the appliance | |
| Venting and air | ||
| Max. equivalent vent length, 2" | 100 ft | Each side per the I&O manual. |
| Max. equivalent vent length, 3" | 150 ft | Each side per the I&O manual. |
| Physical and connections | ||
| Weight | 107 lb | Per the NTI product page. |
| CH water connections | 1 1/4" NPT | Per the NTI product page. |
| DHW connections | 3/4" NPT | |
| Gas connection | 3/4" NPT | Male NPT per the NTI product page. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | NTI publishes LP conversion instructions for this series. |
| Turndown ratio | up to 10:1 | Manufacturer marketing figure on the NTI product page. |
Manuals
- FTVN Series I — Installation Startup Maintenance Instructions, 420011303800, Rev 2.28.23420011303800 Rev 2.28.23
- FTVN Series II — Installation Startup Maintenance Instructions, 420012001400, Rev 10 (06152024)420012001400 Rev 10 · 2024-06-15
Alerts documented for this model
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 1 15
- 1 16
- 1 50
- 1 P1
- 1 P2
- 1 P3
- 2 01
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 4 40
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 02
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 1 15
- 1 16
- 1 50
- 1 P1
- 1 P2
- 1 P3
- 2 01
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 11
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 4 40
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
Frequently asked questions
How much hot water does the FTVN110C deliver?
NTI rates continuous DHW at 2.7 GPM for a 77°F temperature rise. Real delivery falls as incoming water cools, so a site check of supply temperature matters before sizing.
Does the FTVN110C heat as well as the FTVN110?
Yes — both fire at 11 to 110 MBH for space heating at 95% AFUE. The C adds the integrated DHW plate and diverter inside the same 107 lb cabinet.
Is 2.7 GPM enough for two bathrooms?
Not usually for simultaneous draws. If two showers can run at once, the FTVN150C (3.6 GPM) or a heating-only FTVN with an indirect tank is the more reliable combination.
Questions about the NTI Trinity FTVN110C?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- NTI Trinity FTVN110C vs FTVN150CComparison
- IBC SFC 99-1 Superflow vs NTI Trinity FTVN110CComparison
- Navien NCB-240/110H vs NTI Trinity FTVN110CComparison
- NTI Trinity FTVN085Same series
- NTI Trinity FTVN110Same series
- NTI Trinity FTVN150Same series
- NTI Trinity FTVN199Same series
- NTI Trinity FTVN150CSame series
- NTI Trinity FTVN199CSame series
- Trinity FTVN series hub
- Buying guide
Sources and verification
- NTI — FTVN Series product page · accessed September 7, 2026
- NTI — FTVN Series II product page · accessed September 7, 2026
- FTVN Series I — Installation Startup Maintenance Instructions, 420011303800, Rev 2.28.23 · 420011303800 Rev 2.28.23 · accessed September 7, 2026
- FTVN Series II — Installation Startup Maintenance Instructions, 420012001400, Rev 10 (06152024) · 420012001400 Rev 10 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.