Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

IBC SL 10-85 G3 vs SL 14-115 G3

Verdict in brief

The SL 10-85 G3 and SL 14-115 G3 are the two smallest SL G3 boilers and share the same 85 lb weight, water connections and 240-foot 3" vent allowance. The 85 is the only SL G3 rated 96% AFUE and suits low heat-loss homes; the 115 adds roughly 30 MBH of output headroom and a lower 14 MBH minimum fire rate, so size from a heat-loss calculation rather than floor area.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC SL 10-85 G3 and IBC SL 14-115 G3
SpecificationIBC SL 10-85 G3IBC SL 14-115 G3
Input, minimum10.6 MBH14 MBH
Input, maximum85 MBH115 MBH
CSA output, minimum10.1 MBH13.3 MBH
CSA output, maximum79 MBH109 MBH
Efficiency (AFUE)96 %95 %
Turndown ratioup to 8:1up to 8:1
Max. equivalent vent length, 3"240 ft240 ft
Max. equivalent vent length, 2"100 ft100 ft
Water connections1" NPT1" NPT
Weight (empty)85 lb85 lb
Domestic hot waterNot a combi; indirect tank connects directly to the boilerNot a combi; indirect tank connects directly to the boiler

What actually separates them

Both are wall-hung, heating-only condensing boilers on the same V-10 controller with the same fuel options, so the differences are capacity and the 85's higher efficiency rating. IBC rates the SL 10-85 G3 at 96% AFUE and the SL 14-115 G3 at 95%.

The 115's minimum input of 14 MBH is lower than the 85's 10.6 MBH figure looks backwards: it is higher. The 85 fires down to 10.6 MBH and the 115 to 14 MBH, so in a very low-load home the smaller boiler matches mild-weather demand more closely even though the difference is modest.

Weight, water connections (1" NPT) and venting are effectively identical — both allow 100 feet of 2" or 240 feet of 3" per side. The real question is whether the calculated heat loss and hot-water recovery load fit inside 79 MBH of CSA output or need the 109 MBH of the 115.

IBC Technologies

IBC SL 10-85 G3

CurrentSold in Canada
Input
10.6–85 MBH
Output (max)
79 MBH
AFUE
96 %

The IBC SL 10-85 G3 is the smallest SL Series G3 boiler: 10.6 to 85 MBH input with a 96% AFUE rating, wall-hung and available for natural gas or propane. It is the size to consider for compact homes and low heat-loss buildings.

Natural gasPropaneHeating-only

IBC Technologies

IBC SL 14-115 G3

CurrentSold in Canada
Input
14–115 MBH
Output (max)
109 MBH
AFUE
95 %

The IBC SL 14-115 G3 is a wall-hung residential condensing boiler with a 14 to 115 MBH input range and 95% AFUE, running on natural gas or propane. It is the size most often matched to a typical Lower Mainland detached home with radiators or in-floor heat.

Natural gasPropaneHeating-only

Frequently asked questions

Which is more efficient?

The SL 10-85 G3 is rated 96% AFUE and the SL 14-115 G3 95%, per IBC's Canadian pages. In practice the efficiency that matters is whether the boiler modulates to match the home's load.

Are their venting limits the same?

Yes: both allow up to 100 equivalent feet in 2" or 240 in 3" per side.

When does the 115 make more sense?

When the heat-loss calculation (plus any indirect-tank recovery load) exceeds what the 85 can deliver on a design day, or when you want the extra output headroom of the 115 at a modest efficiency cost.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate