IBC Technologies · SL Series G3
IBC SL 10-85 G3
The IBC SL 10-85 G3 is the smallest SL Series G3 boiler: 10.6 to 85 MBH input with a 96% AFUE rating, wall-hung and available for natural gas or propane. It is the size to consider for compact homes and low heat-loss buildings.
Key figures
- Max input
- 85 MBH
- Max CSA output
- 79 MBH
- AFUE
- 96 %
- Min input
- 10.6 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
IBC SL 10-85 G3 in practice
The SL 10-85 G3 is the entry point of the SL G3 range and the only model in the series IBC rates at 96% AFUE. Its minimum input of 10.6 MBH is low enough for well-insulated homes and mild Lower Mainland shoulder seasons, where the boiler can run steadily rather than short-cycle.
It is a heating-only boiler like the rest of the series: domestic hot water comes from an indirect tank connected directly to the boiler, per IBC's documentation. For very small buildings, a combi boiler such as the SFC 99-1 may remove the need for a tank, which is a trade-off worth discussing at consultation.
Venting is 3" Schedule 40 or 3" polypropylene with up to 240 equivalent feet per side, and IBC also allows 2" venting to 100 feet on this model. Those venting options give an installer useful freedom when replacing an old atmospheric boiler in a tight space.
Best suited to
- Compact detached homes, laneway houses and suites with low heat loss
- Well-insulated homes where 85 MBH comfortably exceeds the calculated load
- Anyone replacing a boiler whose heat loss does not justify a 115 MBH unit
Applicability and support
- Model number
- SL 10-85G3
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 10.6 MBH | 3.10 kW |
| Input, maximum | 85 MBH | 24.9 kW |
| Output | ||
| CSA output, minimum | 10.1 MBH | 2.96 kW |
| CSA output, maximum | 79 MBH | 23.1 kW. DOE heating capacity is not published on the IBC pages we cite. |
| Efficiency | ||
| Efficiency (AFUE) | 96 % | 96% AFUE per IBC model page and Canadian brochure. |
| Domestic hot water | ||
| Domestic hot water | Not a combi; indirect tank connects directly to the boiler | |
| Venting and air | ||
| Flue material | 3" Schedule 40 or 3" PPs (80 mm) | |
| Max. equivalent vent length, 3" | 240 ft | Each side; see the installation manual for the equivalent-length method. |
| Max. equivalent vent length, 2" | 100 ft | |
| Air intake | Direct vent or indoor supply | |
| Physical and connections | ||
| Weight (empty) | 85 lb | 39 kg |
| Water connections | 1" NPT | |
| Gas connection | 1/2" NPT | |
| Condensate connection | 3/4" hose | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Conversion kit included per IBC model page. |
| Turndown ratio | up to 8:1 | IBC model page figure. The Canadian brochure headline says up to 10:1. |
| Gas supply pressure | 4 – 14 in. w.c. | |
| Max. operating pressure | 30 psig | |
| Max. water temperature | 190 °F | Electronic limit. |
| Altitude rating | 0 – 12,000 ft | |
Manuals
- Installation & Operating Manual — SL G3 residential, doc 120-276E13120-276E13 · 2026-08-11
- SL Series G3 Brochure (Canada)900-041 R8 · 2019-05-29
Alerts documented for this model
- Error – Ignition trials exceeded
- Error – Water High-Limit
- Error – Low Water Cutoff
- Error: Interlock [1 or 2] Open
- Error: Vent High Limit
- Error – Max. delta T Exceeded
- Error – Low RPM / Air Flow
- Error – Fan Pressure
- Error – Module High Current
- Error – Low Module Current
- Error – Low Water Pressure
- Error – Inlet Pres. Sensor
- Error – See: Status > SIM menu > Status
- Error – Roll Out Switch
- Error – Controller Board
- Error – No Boilernet Comm
- Error – No MAC address
- Error – Flame Signal / Vent Block
- Error – Reversed Flow
- Error – Temp. probe error
- Error – Unhandled error code
- Outlet Limited
- Remote offline
- Unoccupied
- Summer
- Failsafe Setpoint
Frequently asked questions
Is 96% AFUE correct for the SL 10-85 G3?
Yes. IBC's Canadian model page and brochure rate the SL 10-85 G3 at 96% AFUE, while the 115, 160 and 199 models in the same series are rated 95%.
Can the SL 10-85 G3 run on propane?
Yes. It is listed for natural gas or propane and IBC states a conversion kit is included with the unit.
Is 85 MBH enough for my house?
If the calculated heat loss is within the boiler's output range, yes. A heat-loss calculation rather than floor area decides the size, and an oversized boiler short-cycles even if it is smaller than the house 'feels'.
Questions about the IBC SL 10-85 G3?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- IBC SL 10-85G3 — model page · accessed September 7, 2026
- IBC SL Series G3 — series page · accessed September 7, 2026
- SL Series G3 Brochure (Canada), spec table · 900-041 R8 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.