Skip to content
Boilers.caby ROMA Heating & Cooling

IBC Technologies · SL Series G3

IBC SL 10-85 G3

The IBC SL 10-85 G3 is the smallest SL Series G3 boiler: 10.6 to 85 MBH input with a 96% AFUE rating, wall-hung and available for natural gas or propane. It is the size to consider for compact homes and low heat-loss buildings.

CurrentSold in Canada

Key figures

Max input
85 MBH
Max CSA output
79 MBH
AFUE
96 %
Min input
10.6 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

IBC SL 10-85 G3 in practice

The SL 10-85 G3 is the entry point of the SL G3 range and the only model in the series IBC rates at 96% AFUE. Its minimum input of 10.6 MBH is low enough for well-insulated homes and mild Lower Mainland shoulder seasons, where the boiler can run steadily rather than short-cycle.

It is a heating-only boiler like the rest of the series: domestic hot water comes from an indirect tank connected directly to the boiler, per IBC's documentation. For very small buildings, a combi boiler such as the SFC 99-1 may remove the need for a tank, which is a trade-off worth discussing at consultation.

Venting is 3" Schedule 40 or 3" polypropylene with up to 240 equivalent feet per side, and IBC also allows 2" venting to 100 feet on this model. Those venting options give an installer useful freedom when replacing an old atmospheric boiler in a tight space.

Best suited to

  • Compact detached homes, laneway houses and suites with low heat loss
  • Well-insulated homes where 85 MBH comfortably exceeds the calculated load
  • Anyone replacing a boiler whose heat loss does not justify a 115 MBH unit

Applicability and support

Model number
SL 10-85G3
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.

IBC SL 10-85 G3 specifications
SpecificationValueNote
Input
Input, minimum10.6 MBH3.10 kW
Input, maximum85 MBH24.9 kW
Output
CSA output, minimum10.1 MBH2.96 kW
CSA output, maximum79 MBH23.1 kW. DOE heating capacity is not published on the IBC pages we cite.
Efficiency
Efficiency (AFUE)96 %96% AFUE per IBC model page and Canadian brochure.
Domestic hot water
Domestic hot waterNot a combi; indirect tank connects directly to the boiler
Venting and air
Flue material3" Schedule 40 or 3" PPs (80 mm)
Max. equivalent vent length, 3"240 ftEach side; see the installation manual for the equivalent-length method.
Max. equivalent vent length, 2"100 ft
Air intakeDirect vent or indoor supply
Physical and connections
Weight (empty)85 lb39 kg
Water connections1" NPT
Gas connection1/2" NPT
Condensate connection3/4" hose
Operating limits and other
FuelNatural gas or propaneConversion kit included per IBC model page.
Turndown ratioup to 8:1IBC model page figure. The Canadian brochure headline says up to 10:1.
Gas supply pressure4 – 14 in. w.c.
Max. operating pressure30 psig
Max. water temperature190 °FElectronic limit.
Altitude rating0 – 12,000 ft

Frequently asked questions

Is 96% AFUE correct for the SL 10-85 G3?

Yes. IBC's Canadian model page and brochure rate the SL 10-85 G3 at 96% AFUE, while the 115, 160 and 199 models in the same series are rated 95%.

Can the SL 10-85 G3 run on propane?

Yes. It is listed for natural gas or propane and IBC states a conversion kit is included with the unit.

Is 85 MBH enough for my house?

If the calculated heat loss is within the boiler's output range, yes. A heat-loss calculation rather than floor area decides the size, and an oversized boiler short-cycles even if it is smaller than the house 'feels'.

Questions about the IBC SL 10-85 G3?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.