IBC SL 14-115 G3 vs Lochinvar Knight WHB110

Verdict in brief

The IBC SL 14-115 G3 and Lochinvar Knight WHB110 are both 95% AFUE heating-only condensing boilers for detached homes, but the WHB110 is the smaller package: Lochinvar fires 11 to 110 MBH with 102 MBH DOE capacity, while IBC fires 14 to 115 MBH. The Knight's venting is tighter (100 feet of 3" per side, 40 feet of 2") against the SL's 240-foot 3" reach, so a heat-loss calculation plus the vent route decide.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC SL 14-115 G3 and Lochinvar Knight WHB110
SpecificationIBC SL 14-115 G3Lochinvar Knight WHB110
Input, minimum14 MBH11 MBH
Input, maximum115 MBH110 MBH
Efficiency (AFUE)95 %95 %
Flue material3" Schedule 40 or 3" PPs (80 mm)Category IV sealed combustion; PVC, CPVC, polypropylene or stainless steel
Max. equivalent vent length, 3"240 ft100 ft
Max. equivalent vent length, 2"100 ft40 ft
Water connections1" NPT1"
Gas connection1/2" NPT1/2"
Domestic hot waterNot a combi; indirect tank connects directly to the boilerHeating-only boiler

What actually separates them

Both are wall-hung, heating-only condensing boilers rated 95% AFUE on natural gas or propane, and both sit in the 110-115 MBH neighborhood: IBC publishes 14 to 115 MBH input for the SL 14-115 G3 while Lochinvar lists the Knight WHB110 at 11 to 110 MBH with a 102 MBH DOE heating capacity. The WHB110's 11 MBH minimum input is the lower of the two idle points, while the SL carries roughly 5 MBH more top-end headroom.

Venting is where the records diverge most. IBC allows 240 equivalent feet of 3" Schedule 40 or PPs pipe per side, or 100 feet of 2"; Lochinvar's ratings table caps the WHB110 at 100 feet of 3" and just 40 feet of 2" per side. Both makers allow Category IV sealed combustion piping, with a note that Canadian plastic venting must be ULC S636-certified.

Connections and DHW handling are straightforward on both: the SL 14-115 G3 uses 1" NPT water and 1/2" NPT gas, and the WHB110 uses 1" water and 1/2" gas, and both are heating-only boilers that pair with an indirect tank. With similar footprints the decision usually falls to the minimum fire, the vent route available in the mechanical room, and the room-by-room heat-loss calculation.

IBC Technologies

IBC SL 14-115 G3

CurrentSold in Canada
Input
14–115 MBH
Output (max)
109 MBH
AFUE
95 %

The IBC SL 14-115 G3 is a wall-hung residential condensing boiler with a 14 to 115 MBH input range and 95% AFUE, running on natural gas or propane. It is the size most often matched to a typical Lower Mainland detached home with radiators or in-floor heat.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
—
AFUE
95 %

The Knight WHB110 is the mid-size wall-hung Knight: 11 to 110 MBH input at 95% AFUE with 102 MBH DOE heating capacity, and 2" venting limited to 40 equivalent feet.

Natural gasPropaneHeating-only

Frequently asked questions

Which boiler allows a longer vent run?

The IBC SL 14-115 G3 allows 240 equivalent feet of 3" per side versus 100 feet for the Knight WHB110, and 100 feet of 2" versus 40 feet, which can matter in deep basements.

Are both boilers heating-only?

Yes. Each connects to an indirect tank for domestic hot water; neither produces DHW in the appliance.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate