The IBC SL 14-115 G3 and NTI Trinity FTVN150 are both 95% AFUE heating-only condensing boilers with 2" and 3" vent options, but they are sized differently: IBC fires 14 to 115 MBH at 85 lb with 1" water connections, while NTI fires 15 to 150 MBH at 122 lb with 1 1/4" connections and 100 feet of 2" venting. A heat-loss calculation picks the input ceiling; the FTVN150's extra 35 MBH only helps if the house really needs it.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC SL 14-115 G3 and NTI Trinity FTVN150
SpecificationIBC SL 14-115 G3NTI Trinity FTVN150
Input, minimum14 MBH15 MBH
Input, maximum115 MBH150 MBH
Efficiency (AFUE)95 %95 %
Turndown ratioup to 8:1up to 10:1
Weight (empty)85 lb122 lb
FuelNatural gas or propaneNatural gas or propane
Max. equivalent vent length, 3"240 ft150 ft
Max. equivalent vent length, 2"100 ft100 ft
Water connections1" NPT1 1/4" NPT
Gas connection1/2" NPT3/4" NPT
Domestic hot waterNot a combi; indirect tank connects directly to the boilerHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both are wall-hung, heating-only condensing boilers rated 95% AFUE with natural gas or propane listed, and both keep a 2" venting option alongside 3". The capacity story differs: IBC publishes 14 to 115 MBH (4.10 to 33.7 kW) for the SL 14-115 G3, while NTI lists the FTVN150 at 15 to 150 MBH — roughly 35 MBH more headroom at the top and a slightly higher 15 MBH minimum fire.

Both makers publish turndown claims in the same range (up to 8:1 on the IBC page, with its brochure saying 10:1; up to 10:1 per NTI's marketing page), and the low-fire figures are close at 14 and 15 MBH. In a detached home whose calculated load sits near 80-110 MBH, the extra 35 MBH of the FTVN150 is unused capacity, while in a house that genuinely needs 140 MBH the SL 115 falls short regardless of its 240 feet of 3" venting reach.

The installation numbers separate the two clearly: the SL 14-115 G3 weighs 85 lb (39 kg) and uses 1" NPT water connections with 100 feet of 2" or 240 feet of 3" venting per side, while the FTVN150 weighs 122 lb, steps up to 1 1/4" NPT water and 3/4" NPT gas, and NTI allows 100 feet of 2" or 150 feet of 3" per side. Both need an indirect tank for domestic hot water, and both should be selected from a heat-loss calculation.

IBC Technologies

IBC SL 14-115 G3

CurrentSold in Canada
Input
14–115 MBH
Output (max)
109 MBH
AFUE
95 %

The IBC SL 14-115 G3 is a wall-hung residential condensing boiler with a 14 to 115 MBH input range and 95% AFUE, running on natural gas or propane. It is the size most often matched to a typical Lower Mainland detached home with radiators or in-floor heat.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
15–150 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity FTVN150 is the 95% AFUE heating-only FTVN for homes between the 110 and 199 sizes: it fires 15 to 150 MBH, weighs 122 lb, and keeps 2" venting to 100 ft or 3" to 150 ft per side.

Natural gasPropaneHeating-only

Frequently asked questions

Is the FTVN150 always the better pick because it is bigger?

No. Its 150 MBH ceiling only helps when the heat-loss calculation and indirect-tank recovery actually approach that number; otherwise the SL 14-115 G3's lower 14 MBH minimum fire and lighter 85 lb weight are the better fit.

Do both boilers allow 2" venting?

Yes. IBC allows 100 equivalent feet of 2" per side on the SL 14-115 G3, and NTI allows the same 100 feet of 2" on the FTVN150, with 3" limits of 240 and 150 feet respectively.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate