NTI Trinity FTVN150
The NTI Trinity FTVN150 is the 95% AFUE heating-only FTVN for homes between the 110 and 199 sizes: it fires 15 to 150 MBH, weighs 122 lb, and keeps 2" venting to 100 ft or 3" to 150 ft per side.
Key figures
- Max input
- 150 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 15 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI Trinity FTVN150 in practice
The FTVN150 raises the input ceiling to 150 MBH for a 15 lb gain over the 107 lb FTVN110, staying on the family's 1 1/4" NPT CH connections and 3/4" NPT gas connection. As a heating-only boiler it pairs with an indirect tank for domestic hot water, and it carries the same vertical down-fired stainless heat exchanger, ECM pump and up to 10:1 modulation as the rest of the FTVN line.
Its 15 MBH minimum fire sits between the 085's 8.5 MBH and the 199's 19.9 MBH floors, which keeps low-fire behaviour reasonable in mild BC weather while adding headroom for larger radiators, in-floor loops or bigger indirect-tank recovery. A room-by-room heat-loss calculation decides whether the load truly needs more than the 110 can deliver before stepping up to this size.
Best suited to
- Larger detached homes whose heat-loss plus indirect-tank demand exceeds 110 MBH
- Homes with radiators or in-floor loops that need up to about 138 MBH of heating output
- Installers who want the FTVN line's venting flexibility at a mid-range weight of 122 lb
Applicability and support
- Model number
- FTVN150
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 15 MBH | Per the NTI product page. |
| Input, maximum | 150 MBH | Per the NTI product page. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | DOE AFUE per the NTI product page; only the FTVN085 is rated 96%. |
| Domestic hot water | ||
| Domestic hot water | Heating-only; pair with an indirect tank or separate water heater | |
| Venting and air | ||
| Max. equivalent vent length, 2" | 100 ft | Each side per the I&O manual. |
| Max. equivalent vent length, 3" | 150 ft | Each side per the I&O manual. |
| Physical and connections | ||
| Weight | 122 lb | Per the NTI product page. |
| CH water connections | 1 1/4" NPT | Per the NTI product page. |
| Gas connection | 3/4" NPT | Male NPT per the NTI product page. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | NTI publishes LP conversion instructions for this series. |
| Turndown ratio | up to 10:1 | Manufacturer marketing figure on the NTI product page. |
Manuals
- FTVN Series I — Installation Startup Maintenance Instructions, 420011303800, Rev 2.28.23420011303800 Rev 2.28.23
- FTVN Series II — Installation Startup Maintenance Instructions, 420012001400, Rev 10 (06152024)420012001400 Rev 10 · 2024-06-15
Alerts documented for this model
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 1 15
- 1 16
- 1 50
- 1 P1
- 1 P2
- 1 P3
- 2 01
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 4 40
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 02
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 1 15
- 1 16
- 1 50
- 1 P1
- 1 P2
- 1 P3
- 2 01
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 11
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 4 40
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
Frequently asked questions
Is the FTVN150 a combi boiler?
No. It is heating-only at 95% AFUE. If you want heating plus domestic hot water from one FTVN appliance, the FTVN150C combi covers the same 15 to 150 MBH heating range and adds DHW.
What does the FTVN150 weigh?
122 lb per the NTI product page, against 107 lb for the FTVN085 and FTVN110 and 139.5 lb for the FTVN199.
What venting does the FTVN150 allow?
2" runs up to 100 ft or 3" runs up to 150 ft per side, per the I&O manual.
Questions about the NTI Trinity FTVN150?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- NTI Trinity FTVN110 vs FTVN150Comparison
- NTI Trinity FTVN150 vs FTVN199Comparison
- IBC SL 14-115 G3 vs NTI Trinity FTVN150Comparison
- NTI Trinity FTVN085Same series
- NTI Trinity FTVN110Same series
- NTI Trinity FTVN199Same series
- NTI Trinity FTVN110CSame series
- NTI Trinity FTVN150CSame series
- NTI Trinity FTVN199CSame series
- Trinity FTVN series hub
- Buying guide
Sources and verification
- NTI — FTVN Series product page · accessed September 7, 2026
- NTI — FTVN Series II product page · accessed September 7, 2026
- FTVN Series I — Installation Startup Maintenance Instructions, 420011303800, Rev 2.28.23 · 420011303800 Rev 2.28.23 · accessed September 7, 2026
- FTVN Series II — Installation Startup Maintenance Instructions, 420012001400, Rev 10 (06152024) · 420012001400 Rev 10 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.