IBC SL 14-115 G3 vs SL 20-160 G3

Verdict in brief

The SL 14-115 G3 and SL 20-160 G3 are both 95% AFUE heating-only boilers on the same controller, but they differ in reach and installability: the 160 delivers about 35% more maximum output while staying on 1" water connections, yet its 2" vent option drops to 35 feet and it weighs 17 lb more.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC SL 14-115 G3 and IBC SL 20-160 G3
SpecificationIBC SL 14-115 G3IBC SL 20-160 G3
Input, minimum14 MBH20 MBH
Input, maximum115 MBH160 MBH
CSA output, minimum13.3 MBH19 MBH
CSA output, maximum109 MBH147 MBH
Efficiency (AFUE)95 %95 %
Turndown ratioup to 8:1up to 8:1
Max. equivalent vent length, 3"240 ft170 ft
Max. equivalent vent length, 2"100 ft35 ft
Water connections1" NPT1" NPT
Weight (empty)85 lb102 lb
Domestic hot waterNot a combi; indirect tank connects directly to the boilerNot a combi; indirect tank connects directly to the boiler

What actually separates them

Both models run the same V-10 controller, fuels and 3" Schedule 40 / PPs venting and share 1" NPT water connections, so the visible differences are output (109 vs 147 MBH CSA maximum) and weight (85 vs 102 lb). The 160 exists for homes whose heat-loss plus hot-water recovery exceeds the 115 on design days.

The minimum fire rates tell the modulation story: the 115 fires down to 14 MBH and the 160 to 20 MBH. In a home whose winter load is around 80-100 MBH both cycle similarly, but in a mild shoulder season the 115 tracks low demand a little more closely.

Venting is where the 160 asks for more planning: 2" venting is allowed only to 35 equivalent feet (against 100 on the 115), so most 160 installations run 3" pipe to its 170-foot limit. The extra 17 lb also changes the wall-mounting and handling plan.

IBC Technologies

IBC SL 14-115 G3

CurrentSold in Canada
Input
14–115 MBH
Output (max)
109 MBH
AFUE
95 %

The IBC SL 14-115 G3 is a wall-hung residential condensing boiler with a 14 to 115 MBH input range and 95% AFUE, running on natural gas or propane. It is the size most often matched to a typical Lower Mainland detached home with radiators or in-floor heat.

Natural gasPropaneHeating-only

IBC Technologies

IBC SL 20-160 G3

CurrentSold in Canada
Input
20–160 MBH
Output (max)
147 MBH
AFUE
95 %

The IBC SL 20-160 G3 is the 160 MBH member of the SL Series G3: a wall-hung, 95% AFUE condensing boiler for natural gas or propane, bridging the 115 and 199 models for homes with higher heat loss or hot-water loads.

Natural gasPropaneHeating-only

Frequently asked questions

Can the SL 20-160 G3 use 2" venting like the 115?

Technically yes, but only to 35 equivalent feet per side versus 100 feet on the 115. In practice most 160 installations use 3" pipe, which is allowed to 170 feet.

Is the 160 worth it over the 115?

Only if the heat-loss calculation and hot-water demand genuinely exceed the 115's output. Extra capacity you do not use just means the boiler runs at higher minimum fire and condenses less.

Do both models connect the same way?

Both use 1" NPT water connections and 1/2" NPT gas; the 160 is 17 lb heavier at 102 lb empty.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate