IBC SL 20-160 G3 vs SL 30-199 G3

Verdict in brief

The SL 20-160 G3 and SL 30-199 G3 are the two largest SL G3 models, both 95% AFUE, and the choice is driven by output and installation weight: the 199 adds about 34 MBH of maximum CSA output but requires 3" venting only (150 feet), steps up to 1 1/4" water connections and weighs 152 lb against the 160's 102 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC SL 20-160 G3 and IBC SL 30-199 G3
SpecificationIBC SL 20-160 G3IBC SL 30-199 G3
Input, minimum20 MBH32 MBH
Input, maximum160 MBH199 MBH
CSA output, minimum19 MBH30 MBH
CSA output, maximum147 MBH181.3 MBH
Efficiency (AFUE)95 %95 %
Turndown ratioup to 8:1up to 8:1
Max. equivalent vent length, 3"170 ft150 ft
Max. equivalent vent length, 2"35 ft—
Water connections1" NPT1 1/4" NPT
Weight (empty)102 lb152 lb
Domestic hot waterNot a combi; indirect tank connects directly to the boilerNot a combi; indirect tank connects directly to the boiler

What actually separates them

Both boilers share the V-10 controller, 95% AFUE and natural-gas-or-propane operation, and both are heating-only with a direct-connected indirect tank. The 199 delivers up to 181.3 MBH CSA output against the 160's 147 MBH — the difference that decides large homes and small multi-suite plants.

The 199's minimum input of 32 MBH is well above the 160's 20 MBH. In any building whose load is under about 120 MBH, the 199 spends more time at or near its minimum fire, which favours the 160 even when both could technically do the job.

Installation differences matter on site: the 199 is 3" venting only to 150 equivalent feet (no 2" option, 30 feet of flexible PPs), uses 1 1/4" NPT water connections, and at 152 lb needs a stout wall and a lifting plan. The 160 keeps 1" connections and allows 35 feet of 2" venting.

IBC Technologies

IBC SL 20-160 G3

CurrentSold in Canada
Input
20–160 MBH
Output (max)
147 MBH
AFUE
95 %

The IBC SL 20-160 G3 is the 160 MBH member of the SL Series G3: a wall-hung, 95% AFUE condensing boiler for natural gas or propane, bridging the 115 and 199 models for homes with higher heat loss or hot-water loads.

Natural gasPropaneHeating-only

IBC Technologies

IBC SL 30-199 G3

CurrentSold in Canada
Input
32–199 MBH
Output (max)
181.3 MBH
AFUE
95 %

The IBC SL 30-199 G3 is the largest residential SL G3 boiler: 32 to 199 MBH input, 95% AFUE, natural gas or propane. It suits large homes, homes with high hot-water demand through an indirect tank, and some small multi-suite buildings.

Natural gasPropaneHeating-only

Frequently asked questions

When is the 199 required over the 160?

When the heat-loss calculation plus hot-water recovery demand more than about 147 MBH of output. Below that, the 160's lower minimum fire rate and lighter, simpler installation usually win.

Do both boilers vent the same way?

No. The 160 allows up to 35 feet of 2" and 170 feet of 3" per side; the 199 is 3" only, to 150 feet per side.

Is the 199's 1 1/4" connection a problem?

It is a difference to plan for, not a problem: near-boiler piping must step up to match, and the boiler's higher flow rates need pipe sizing that a technician confirms.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.