IBC Technologies · SL Series G3
IBC SL 30-199 G3
The IBC SL 30-199 G3 is the largest residential SL G3 boiler: 32 to 199 MBH input, 95% AFUE, natural gas or propane. It suits large homes, homes with high hot-water demand through an indirect tank, and some small multi-suite buildings.
Key figures
- Max input
- 199 MBH
- Max CSA output
- 181.3 MBH
- AFUE
- 95 %
- Min input
- 32 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
IBC SL 30-199 G3 in practice
At 199 MBH input and 181.3 MBH CSA output, the SL 30-199 G3 is often the candidate when a large detached home, a laneway-plus-main-house arrangement or a small strata building needs one wall-hung appliance instead of a floor-standing boiler. Its 32 MBH minimum input is still low enough to modulate through shoulder seasons.
Venting is 3" only on this model with a maximum equivalent length of 150 feet per side; there is no 2" option and flexible polypropylene is limited to 30 feet. Those limits affect where the boiler can be mounted in a basement or mechanical room, which is one of the first things assessed on a site visit.
Water connections step up to 1 1/4" NPT, and at 152 lb empty the boiler needs a suitable wall and lifting plan. Like the rest of the series it is heating-only with an indirect tank for domestic hot water.
Best suited to
- Large detached homes with several heating zones
- Homes with high domestic hot-water demand via an indirect tank
- Small multi-suite or strata buildings where a single wall-hung boiler is appropriate after a heat-loss assessment
Applicability and support
- Model number
- SL 30-199G3
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 32 MBH | 9.37 kW |
| Input, maximum | 199 MBH | 58.3 kW |
| Output | ||
| CSA output, minimum | 30 MBH | 8.8 kW |
| CSA output, maximum | 181.3 MBH | 53.1 kW. DOE heating capacity is not published on the IBC pages we cite. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | Annual fuel utilization efficiency as published by IBC. |
| Domestic hot water | ||
| Domestic hot water | Not a combi; indirect tank connects directly to the boiler | |
| Venting and air | ||
| Flue material | 3" Schedule 40 or 3" PPs (80 mm) | |
| Max. equivalent vent length, 3" | 150 ft | Each side; see the installation manual for the equivalent-length method. |
| Air intake | Direct vent or indoor supply | |
| Physical and connections | ||
| Weight (empty) | 152 lb | 69 kg |
| Water connections | 1 1/4" NPT | |
| Gas connection | 1/2" NPT | |
| Condensate connection | 3/4" hose | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Conversion kit included per IBC model page. |
| Turndown ratio | up to 8:1 | IBC model page figure. The Canadian brochure headline says up to 10:1. |
| Gas supply pressure | 4 – 14 in. w.c. | |
| Max. operating pressure | 30 psig | |
| Max. water temperature | 190 °F | Electronic limit. |
| Altitude rating | 0 – 12,000 ft | |
Manuals
- Installation & Operating Manual — SL G3 residential, doc 120-276E13120-276E13 · 2026-08-11
- SL Series G3 Brochure (Canada)900-041 R8 · 2019-05-29
Alerts documented for this model
- Error – Ignition trials exceeded
- Error – Water High-Limit
- Error – Low Water Cutoff
- Error: Interlock [1 or 2] Open
- Error: Vent High Limit
- Error – Max. delta T Exceeded
- Error – Low RPM / Air Flow
- Error – Fan Pressure
- Error – Module High Current
- Error – Low Module Current
- Error – Low Water Pressure
- Error – Inlet Pres. Sensor
- Error – See: Status > SIM menu > Status
- Error – Roll Out Switch
- Error – Controller Board
- Error – No Boilernet Comm
- Error – No MAC address
- Error – Flame Signal / Vent Block
- Error – Reversed Flow
- Error – Temp. probe error
- Error – Unhandled error code
- Outlet Limited
- Remote offline
- Unoccupied
- Summer
- Failsafe Setpoint
Frequently asked questions
Can the SL 30-199 G3 be vented in 2" pipe?
No. IBC lists 3" venting only for this model, with a 150-foot maximum equivalent length per side and flexible PPs limited to 30 feet.
Is 199 MBH too large for my house?
Possibly. Oversizing causes short cycling and wastes fuel. A heat-loss calculation, not square footage, determines the right input, and the smaller SL 14-115 G3 covers many detached homes.
Does ROMA install the SL 30-199 G3?
ROMA installs and services gas boilers across Greater Vancouver. Whether this model is supplied for your project is confirmed at consultation.
Questions about the IBC SL 30-199 G3?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- IBC SL 20-160 G3 vs SL 30-199 G3Comparison
- IBC SL 14-115 G3 vs SL 30-199 G3Comparison
- IBC SL 30-199 G3 vs Viessmann Vitodens 100-W B1HE-199Comparison
- IBC SL 30-199 G3 vs NTI Trinity TFTN199Comparison
- IBC SL 30-199 G3 vs Lochinvar Knight WHB199Comparison
- IBC SL 10-85 G3Same series
- IBC SL 14-115 G3Same series
- IBC SL 20-160 G3Same series
- SL Series G3 series hub
- Buying guide
Sources and verification
- IBC SL 30-199G3 — model page · accessed September 7, 2026
- SL Series G3 Brochure (Canada), spec table · 900-041 R8 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.