IBC SL 30-199 G3 vs Lochinvar Knight WHB199

Verdict in brief

The IBC SL 30-199 G3 and Lochinvar Knight WHB199 are both 95% AFUE, 199 MBH-input heating-only condensing boilers with 3" venting only and 1 1/4" water connections, but they differ at the bottom and on the wall: IBC fires from 32 MBH minimum at 152 lb, while the Knight fires from 19.9 MBH. Both vent 3" to 150 or 100 equivalent feet per side; a heat-loss calculation picks the low-fire floor.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC SL 30-199 G3 and Lochinvar Knight WHB199
SpecificationIBC SL 30-199 G3Lochinvar Knight WHB199
Input, minimum32 MBH19.9 MBH
Input, maximum199 MBH199 MBH
Efficiency (AFUE)95 %95 %
Flue material3" Schedule 40 or 3" PPs (80 mm)Category IV sealed combustion; PVC, CPVC, polypropylene or stainless steel
Max. equivalent vent length, 3"150 ft100 ft
Water connections1 1/4" NPT1-1/4"
Gas connection1/2" NPT1/2"
Domestic hot waterNot a combi; indirect tank connects directly to the boilerHeating-only boiler

What actually separates them

Both boilers reach 199 MBH maximum input at 95% AFUE and are heating-only wall-hung units, so they compete for the same large-home and small multi-suite loads. The recorded difference begins at low fire: IBC lists 32 MBH minimum input for the SL 30-199 G3, while Lochinvar lists 19.9 MBH for the Knight WHB199, which also carries a 183 MBH DOE heating capacity against the SL's 181.3 MBH CSA output figure.

Both are 3" venting-only installations, but the reach differs: IBC allows 150 equivalent feet of 3" per side while Lochinvar's ratings table caps the WHB199 at 100 feet per side, with both makers permitting Category IV PVC, CPVC, polypropylene or stainless steel (ULC S636-certified in Canada). Neither unit offers a 2" route, so the mechanical room's distance to the vent terminal is a first-pass constraint.

Water connections match at 1 1/4" NPT on both boilers and gas stays at 1/2" NPT, but weight diverges: IBC publishes 152 lb (69 kg) for the SL 30-199 G3 while the Knight WHB199's table does not list an empty weight in the same basis. Both pair with an indirect tank for hot water, and both should be sized from a heat-loss calculation since their higher minimum fires make oversizing costly in mild weather.

IBC Technologies

IBC SL 30-199 G3

CurrentSold in Canada
Input
32–199 MBH
Output (max)
181.3 MBH
AFUE
95 %

The IBC SL 30-199 G3 is the largest residential SL G3 boiler: 32 to 199 MBH input, 95% AFUE, natural gas or propane. It suits large homes, homes with high hot-water demand through an indirect tank, and some small multi-suite buildings.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
—
AFUE
95 %

The Knight WHB199 is the 199 MBH wall-hung Knight: 19.9 to 199 MBH input at 95% AFUE, stepping up to 1 1/4" water connections and 3" venting to 100 equivalent feet.

Natural gasPropaneHeating-only

Frequently asked questions

Which 199 MBH boiler has the lower minimum fire?

The Lochinvar Knight WHB199 fires down to 19.9 MBH against 32 MBH for the IBC SL 30-199 G3, giving the Knight more headroom before short-cycling at part load.

Is there a 2" venting option on either boiler?

No. Both the IBC SL 30-199 G3 and the Knight WHB199 install in 3" pipe only, with 150 and 100 equivalent feet per side respectively.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.