Lochinvar · Knight Wall Mount (WHB)

Lochinvar Knight WHB199

The Knight WHB199 is the 199 MBH wall-hung Knight: 19.9 to 199 MBH input at 95% AFUE, stepping up to 1 1/4" water connections and 3" venting to 100 equivalent feet.

CurrentSold in Canada

Key figures

Max input
199 MBH
Max CSA output
AFUE
95 %
Min input
19.9 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Knight WHB199 in practice

The WHB199 lifts the wall-hung Knight to a nominal 199,000 BTU/h ceiling: input spans 19.9 to 199 MBH with 183 MBH of DOE heating capacity and a 159 MBH AHRI net rating at 95% AFUE. Its minimum fire of 19.9 MBH is the highest in the smaller half of the line, so the heat-loss calculation should genuinely need the ceiling before this size is chosen.

The larger input brings the first connection step: water fittings move from 1" to 1-1/4" and water content rises to 5.2 gallons, while the gas connection stays 1/2". Venting is 3" to 100 equivalent feet, and as a heating-only boiler it pairs with the Squire indirect tank for domestic hot water.

Best suited to

  • Large homes and small multi-suite buildings whose load approaches 199 MBH
  • Systems with an indirect tank sized for high hot-water recovery
  • Projects where 1-1/4" near-boiler piping is already planned

Applicability and support

Model number
WHB199L
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Knight WHB199 specifications
SpecificationValueNote
Input
Heating input, minimum19.9 MBHPer the I&O ratings table.
Heating input, maximum199 MBHPer the I&O ratings table.
Output
DOE heating capacity183 MBHDOE heating capacity per the I&O ratings table.
AHRI net water rating159 MBHNet AHRI rating based on a piping and pickup allowance of 1.15.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the I&O ratings table.
Domestic hot water
Domestic hot waterHeating-only boilerPairs with the Squire indirect water heater or another indirect tank; the Knight is heating-only.
Venting and air
VentingCategory IV sealed combustion; PVC, CPVC, polypropylene or stainless steelIn Canada, plastic venting must be a ULC S636-certified system.
Max. equivalent vent/air length, 3"100 ftTable 3D (air intake/vent piping sizes), I&O manual.
Physical and connections
Water content5.2 galPer the I&O ratings table.
Space-heating water connections1-1/4"Per the I&O ratings table.
Gas connection1/2"Per the I&O ratings table.

Frequently asked questions

What connections does the WHB199 use?

1-1/4" heating water connections with a 1/2" gas connection, and a 5.2-gallon water content, per the I&O ratings table.

Is the WHB199's minimum fire a concern?

At 19.9 MBH it is the highest minimum among the 055-199 sizes, so in a home whose load is well under the boiler's ceiling the unit will cycle more in mild weather. Sizing should follow a heat-loss calculation.

Questions about the Lochinvar Knight WHB199?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate