IBC SL 30-199 G3 vs NTI Trinity TFTN199

Verdict in brief

The IBC SL 30-199 G3 and NTI Trinity TFTN199 are both 95% AFUE, 199 MBH-input heating-only condensing boilers, yet they modulate and install very differently: the SL fires from 32 MBH minimum, weighs 152 lb, vents 3" only to 150 feet, and connects 1 1/4"; the TFTN199 fires from 19.9 MBH, weighs 140 lb with water, and vents 2" to 100 feet or 3" to 150 feet. A heat-loss calculation decides which low-fire floor and package fit.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC SL 30-199 G3 and NTI Trinity TFTN199
SpecificationIBC SL 30-199 G3NTI Trinity TFTN199
Input, minimum32 MBH19.9 MBH
Input, maximum199 MBH199 MBH
Efficiency (AFUE)95 %95 %
Weight (empty)152 lb140 lb
FuelNatural gas or propaneNatural gas or propane
Max. equivalent vent length, 3"150 ft150 ft
Water connections1 1/4" NPT1 1/4" NPT
Gas connection1/2" NPT3/4" NPT
Domestic hot waterNot a combi; indirect tank connects directly to the boilerHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both boilers reach 199 MBH maximum input (58.3 kW published on each maker's page) at 95% AFUE, and both are heating-only, so they serve the same large homes and small multi-suite buildings. The modulation gap is wide: the SL 30-199 G3 needs 32 MBH minimum input (9.37 kW), while the TFTN199 fires down to 19.9 MBH, giving NTI's model a noticeably lower part-load floor in mild weather.

Venting also differs in kind, not just length. IBC lists 3" pipe only for the SL 30-199 G3, to 150 equivalent feet per side; NTI allows both 2" to 100 feet and 3" to 150 feet per side on the TFTN199, which is the more flexible answer in a retrofit where a 2" route already exists. Water connections are the same nominal step: 1 1/4" NPT on each boiler.

Weight and mounting differ at the margin: the SL 30-199 G3 is 152 lb (69 kg) empty, while NTI lists the TFTN199 at 140 lb with water. Both use 3/4" NPT gas connections and both need an indirect tank for domestic hot water. Because neither boiler modulates below roughly 20-32 MBH, the home's true low-load behavior from a heat-loss calculation matters as much as the 199 MBH headline.

IBC Technologies

IBC SL 30-199 G3

CurrentSold in Canada
Input
32–199 MBH
Output (max)
181.3 MBH
AFUE
95 %

The IBC SL 30-199 G3 is the largest residential SL G3 boiler: 32 to 199 MBH input, 95% AFUE, natural gas or propane. It suits large homes, homes with high hot-water demand through an indirect tank, and some small multi-suite buildings.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity TFTN199 is the 95% AFUE wall-hung TFTN at the classic 199 MBH mark: 19.9 to 199 MBH input, 140 lb with water, still on 1 1/4" NPT CH connections with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only

Frequently asked questions

Which 199 MBH boiler fires lower?

The NTI TFTN199 drops to 19.9 MBH minimum input versus 32 MBH on the IBC SL 30-199 G3, so it handles mild-weather part loads with less cycling.

Can the TFTN199 vent in 2" pipe when the SL 199 cannot?

Yes. NTI allows 2" venting to 100 feet per side on the TFTN199, while the IBC SL 30-199 G3 is 3" only to 150 feet per side.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.