Verdict in brief

The two floor-standing combis share the 22 x 41 x 22 inch chassis, the Caleffi 548 separator, the internal circulator and 95% AFUE, but the 199 adds input ceiling (199,000 vs 155,000 BTU/h) and DHW delivery (5.3 vs 4.0 GPM at a 70°F rise). The 155 alone lists a 2-inch vent option; the 199 vents 3-inch up to 100 feet.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Ideal Exalt Floor Combi 155 and Ideal Exalt Floor Combi 199
SpecificationIdeal Exalt Floor Combi 155Ideal Exalt Floor Combi 199
Input, minimum (NG & LP)19.375 MBH24.875 MBH
Input, maximum (NG & LP)155 MBH199 MBH
Efficiency (AFUE)95 %95 %
Turndown ratio8:18:1
DOE heating capacity142 MBH184 MBH
AHRI net rating123 MBH159 MBH
DHW output at 70°F rise4 GPM5.3 GPM
DHW minimum flow rate0.5 GPM0.5 GPM
Weight181 lb191 lb
Domestic hot waterCombi: on-demand DHW via an integrated plate heat exchangerCombi: on-demand DHW via an integrated plate heat exchanger

What actually separates them

Both floor combis heat the building and produce domestic hot water on demand. Heating ranges are 19,375 to 155,000 BTU/h (combi 155) and 24,875 to 199,000 BTU/h (combi 199), both at 95% AFUE with an 8:1 turndown and DOE capacities of 142 and 184 MBH. DHW output is 4.0 GPM at a 70°F rise on the 155 and 5.3 GPM on the 199, with the same 0.5 GPM minimum flow and 150 psi maximum DHW pressure.

Both ship with the floor platform's Caleffi 548 series separator with air elimination and a pre-installed internal circulator, with left-or-right water and gas connections. Venting: the 155 lists 2-inch up to 33 equivalent feet and 3-inch up to 100 feet; the 199 lists 3-inch up to 100 feet.

Weight rises from 181 to 191 lb and water volume from 3 to 4 gallons in the same cabinet. Both use CTRLMax with DHW priority, outdoor reset and plain-text diagnostics, and both are published in natural-gas and propane versions. Households whose simultaneous hot-water demand exceeds 4.0 GPM are the ones that need the 199.

CurrentCanadian status unknown
Input
19.375–155 MBH
Output (max)
AFUE
95 %

The Ideal Exalt Floor Combi 155 is a floor-standing combi: 19,375 to 155,000 BTU/h heating input at 95% AFUE with 4.0 GPM on-demand DHW at a 70°F rise, an included separator and circulator, in a 181 lb chassis.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
24.875–199 MBH
Output (max)
AFUE
95 %

The Ideal Exalt Floor Combi 199 is the largest floor-standing combi in the Exalt line: 24,875 to 199,000 BTU/h heating input at 95% AFUE with 5.3 GPM on-demand DHW at a 70°F rise in a 191 lb chassis.

Natural gasPropaneCombi

Frequently asked questions

How much more hot water does the floor combi 199 deliver?

5.3 GPM at a 70°F rise against 4.0 GPM for the 155, with 4.9 vs 3.7 GPM at 75°F and 4.6 vs 3.5 GPM at 80°F.

Do both floor combis include a separator and pump?

Yes — both list the Caleffi 548 series separator with air elimination and a pre-installed internal circulator.

Which floor combi offers 2-inch venting?

The combi 155, up to 33 equivalent feet. The combi 199 lists 3-inch venting up to 100 feet.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate