Skip to content
Boilers.caby ROMA Heating & Cooling

Ideal Heating · Exalt Floor Combi

Ideal Exalt Floor Combi 155

The Ideal Exalt Floor Combi 155 is a floor-standing combi: 19,375 to 155,000 BTU/h heating input at 95% AFUE with 4.0 GPM on-demand DHW at a 70°F rise, an included separator and circulator, in a 181 lb chassis.

CurrentCanadian status unknown

Key figures

Max input
155 MBH
Max CSA output
AFUE
95 %
Min input
19.375 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Ideal Exalt Floor Combi 155 in practice

The Exalt Floor Combi 155 combines the floor-standing Exalt chassis with on-demand domestic hot water. Heating input runs 19,375 to 155,000 BTU/h at 95% AFUE with an 8:1 turndown, a 142 MBH DOE heating capacity and a 123 MBH AHRI net rating. The DHW side delivers 4.0 GPM at a 70°F rise, 3.7 GPM at 75°F and 3.5 GPM at 80°F, with a 0.5 GPM minimum flow and a 150 psi maximum DHW pressure.

The unit measures 22 x 41 x 22 inches and weighs 181 lb with 3 gallons of water volume. It ships with the Caleffi 548 series separator with air elimination and a pre-installed internal circulator — the features that distinguish the floor platform from the wall models — and vents with 2-inch pipe up to 33 equivalent feet or 3-inch up to 100 feet. The DHW temperature ceiling is 150°F (65°C) against a 185°F (85°C) central-heating maximum.

CTRLMax provides DHW priority, outdoor reset and plain-text diagnostics. The combi replaces a boiler-and-tank pair where the mechanical room has floor space; homes whose hot-water demand exceeds 4.0 GPM at a 70°F rise step to the combi 199. Natural-gas (IDEXFS155C) and propane (IDEXFS155CLP) versions are published. No explicit Canadian sales statement was found on the official pages checked on 2026-09-09; the Exalt and Gallant submittals list ANSI Z21.13 and CSA 4.9 compliance, so Boilers.ca records canadianStatus as unknown.

Best suited to

  • Homes wanting a floor-standing combi with factory-mounted separation and circulation
  • Households whose DHW demand stays within 4.0 GPM at a 70°F rise
  • Retrofits replacing both a floor-standing boiler and a DHW tank

Applicability and support

Model number
IDEXFS155C (NG) / IDEXFS155CLP (LP)
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Ideal Heating. Units are shown with every value; notes flag conflicting sources or missing figures.

Ideal Exalt Floor Combi 155 specifications
SpecificationValueNote
Input
Input, minimum (NG & LP)19.375 MBH19,375 BTU/h per the official model table
Input, maximum (NG & LP)155 MBH155,000 BTU/h per the official model table
Output
DOE heating capacity142 MBHPer the official model table.
AHRI net rating123 MBHPer the official model table.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the official model table.
Domestic hot water
DHW output at 70°F rise4 GPMPer the official model table.
DHW output at 75°F rise3.7 GPMPer the official model table.
DHW output at 80°F rise3.5 GPMPer the official model table.
DHW minimum flow rate0.5 GPMPer the official model table.
DHW maximum operating pressure150 psiPer the official model table.
Maximum DHW flow temperature150 °F150°F (65°C) per the official model table.
Domestic hot waterCombi: on-demand DHW via an integrated plate heat exchanger
Venting and air
Vent / air connections3 in
Maximum vent length, 3 in100 ftPer the official model table.
Maximum vent length, 2 in33 ftPer the official model table.
Physical and connections
Weight181 lb
Width22 in
Height41 in
Depth22 in
Operating limits and other
Turndown ratio8:1Per the official model table.
Gas connection (MNPT)3/4 in
Supply / return connections (MNPT)1 in
Water volume3 galPer the official model table.
Maximum CH flow temperature185 °F185°F (85°C) per the official model table.

Frequently asked questions

What DHW output does the Exalt Floor Combi 155 provide?

4.0 GPM at a 70°F rise, 3.7 GPM at 75°F and 3.5 GPM at 80°F, with a 0.5 GPM minimum flow rate and a 150 psi maximum DHW operating pressure.

What is the heating capacity of the Exalt Floor Combi 155?

19,375 to 155,000 BTU/h input at 95% AFUE with an 8:1 turndown, a 142 MBH DOE heating capacity and a 123 MBH AHRI net rating.

Does the Exalt Floor Combi 155 include a separator and pump?

Yes — the official model page lists a Caleffi 548 series separator with air elimination and a pre-installed internal circulator on the floor combi chassis.

Questions about the Ideal Exalt Floor Combi 155?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate