Skip to content
Boilers.caby ROMA Heating & Cooling

Ideal Heating · Exalt Floor Combi

Ideal Exalt Floor Combi 199

The Ideal Exalt Floor Combi 199 is the largest floor-standing combi in the Exalt line: 24,875 to 199,000 BTU/h heating input at 95% AFUE with 5.3 GPM on-demand DHW at a 70°F rise in a 191 lb chassis.

CurrentCanadian status unknown

Key figures

Max input
199 MBH
Max CSA output
AFUE
95 %
Min input
24.875 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Ideal Exalt Floor Combi 199 in practice

The Exalt Floor Combi 199 is the top of the Exalt combi range. Heating input runs 24,875 to 199,000 BTU/h at 95% AFUE with an 8:1 turndown, a 184 MBH DOE heating capacity and a 159 MBH AHRI net rating. Its published DHW delivery — 5.3 GPM at a 70°F rise, 4.9 GPM at 75°F and 4.6 GPM at 80°F — is the highest in the Exalt family, matching the wall combi 199.

The floor chassis measures 22 x 41 x 22 inches, weighs 191 lb and holds 4 gallons, with the Caleffi 548 series separator with air elimination and a pre-installed internal circulator included. Venting is 3-inch up to 100 equivalent feet; the 2-inch option appears on the combi 155 only. The DHW maximum is 150°F (65°C) and the maximum DHW pressure is 150 psi.

CTRLMax provides DHW priority, outdoor reset and plain-text diagnostics. The model is intended for larger homes with a mechanical-room floor where one appliance can cover both space heating and hot water; the published submittal documents it for specification. Natural-gas (IDEXFS199C) and propane (IDEXFS199CLP) versions are published. No explicit Canadian sales statement was found on the official pages checked on 2026-09-09; the Exalt and Gallant submittals list ANSI Z21.13 and CSA 4.9 compliance, so Boilers.ca records canadianStatus as unknown.

Best suited to

  • Larger homes wanting one floor-standing appliance for heat and hot water
  • Households needing the full 5.3 GPM DHW delivery at a 70°F rise
  • Installations that value factory-mounted separation and circulation

Applicability and support

Model number
IDEXFS199C (NG) / IDEXFS199CLP (LP)
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Ideal Heating. Units are shown with every value; notes flag conflicting sources or missing figures.

Ideal Exalt Floor Combi 199 specifications
SpecificationValueNote
Input
Input, minimum (NG & LP)24.875 MBH24,875 BTU/h per the official model table
Input, maximum (NG & LP)199 MBH199,000 BTU/h per the official model table
Output
DOE heating capacity184 MBHPer the official model table.
AHRI net rating159 MBHPer the official model table.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the official model table.
Domestic hot water
DHW output at 70°F rise5.3 GPMPer the official model table.
DHW output at 75°F rise4.9 GPMPer the official model table.
DHW output at 80°F rise4.6 GPMPer the official model table.
DHW minimum flow rate0.5 GPMPer the official model table.
DHW maximum operating pressure150 psiPer the official model table.
Maximum DHW flow temperature150 °F150°F (65°C) per the official model table.
Domestic hot waterCombi: on-demand DHW via an integrated plate heat exchanger
Venting and air
Vent / air connections3 in
Maximum vent length, 3 in100 ftPer the official model table.
Physical and connections
Weight191 lb
Width22 in
Height41 in
Depth22 in
Operating limits and other
Turndown ratio8:1Per the official model table.
Gas connection (MNPT)3/4 in
Supply / return connections (MNPT)1 in
Water volume4 galPer the official model table.
Maximum CH flow temperature185 °F185°F (85°C) per the official model table.

Frequently asked questions

What is the DHW output of the Exalt Floor Combi 199?

5.3 GPM at a 70°F rise, 4.9 GPM at 75°F and 4.6 GPM at 80°F, with a 0.5 GPM minimum flow rate, per the official model table.

What is the heating range of the Exalt Floor Combi 199?

24,875 to 199,000 BTU/h input at 95% AFUE with an 8:1 turndown, a 184 MBH DOE heating capacity and a 159 MBH AHRI net rating.

How heavy is the Exalt Floor Combi 199?

191 lb in a 22 x 41 x 22 inch cabinet with 4 gallons of water volume, per the official model table.

Questions about the Ideal Exalt Floor Combi 199?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate