Both the Ideal Exalt Wall 110 and the Ideal Exalt Wall 199 belong to the Ideal Heating Exalt Wall (heat-only) line of condensing boilers. The Ideal Exalt Wall 110 is rated 13.75–110 MBH input, 102 MBH DOE heating capacity and 95% AFUE, and the Ideal Exalt Wall 199 is rated 24.875–199 MBH input, 184 MBH DOE heating capacity and 95% AFUE. Ideal Exalt Wall 199 lists 89 MBH more input than Ideal Exalt Wall 110 (199 MBH against 110 MBH). Both list the same published AFUE of 95%. Ideal Exalt Wall 199 lists 31 lb more shipping weight than Ideal Exalt Wall 110 (119 lb against 88 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Ideal Exalt Wall 110 and Ideal Exalt Wall 199
SpecificationIdeal Exalt Wall 110Ideal Exalt Wall 199
Input, minimum (NG & LP)13.75 MBH24.875 MBH
Input, maximum (NG & LP)110 MBH199 MBH
Efficiency (AFUE)95 %95 %
Turndown ratio8:18:1
Domestic hot waterHeating-only; pair with a separate DHW sourceHeating-only; pair with a separate DHW source
Weight88 lb119 lb
Height26 in26 in
Width21.75 in21.75 in
Depth16.5 in16.5 in
Maximum vent length, 3 in100 ft100 ft
Supply / return connections (MNPT)1 in1 in
Gas connection (MNPT)3/4 in3/4 in
DOE heating capacity102 MBH184 MBH
AHRI net rating89 MBH159 MBH
Vent / air connections3 in3 in
Water volume2 gal4 gal
Maximum CH flow temperature185 °F185 °F

What actually separates them

Published ratings: the Ideal Exalt Wall 110 is rated 13.75–110 MBH input, 102 MBH DOE heating capacity and 95% AFUE; the Ideal Exalt Wall 199 is rated 24.875–199 MBH input, 184 MBH DOE heating capacity and 95% AFUE. Ideal Exalt Wall 199 lists 89 MBH more input than Ideal Exalt Wall 110 (199 MBH against 110 MBH). Both list the same published AFUE of 95%.

Ideal Exalt Wall 199 lists 31 lb more shipping weight than Ideal Exalt Wall 110 (119 lb against 88 lb). The water volume differs: the Ideal Exalt Wall 110 lists 2 gal, while the Ideal Exalt Wall 199 lists 4 gal.

Both records print the same AFUE (95%), turndown (8:1), domestic-hot-water arrangement (Heating-only; pair with a separate DHW source) and height (26 in), per the cited sources.

CurrentCanadian status unknown
Input
13.75–110 MBH
Output (max)
AFUE
95 %

The Ideal Exalt Wall 110 is the smallest heat-only model in the Exalt Wall line: 13,750 to 110,000 BTU/h input at 95% AFUE, 8:1 turndown and an 88 lb wall-hung cabinet, with 2-inch venting up to 28 feet or 3-inch up to 100 feet.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
24.875–199 MBH
Output (max)
AFUE
95 %

The Ideal Exalt Wall 199 is the largest heat-only model in the Exalt Wall line: 24,875 to 199,000 BTU/h input at 95% AFUE, 8:1 turndown and a 119 lb cabinet with 3-inch venting up to 100 feet.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The Ideal Exalt Wall 199 lists 199 MBH, against 110 MBH on the Ideal Exalt Wall 110, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 95%.

How much heavier is the Ideal Exalt Wall 199?

It ships at 119 lb against 88 lb for the Ideal Exalt Wall 110, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate