Ideal Gallant Wall 250 vs 299

Verdict in brief

The Gallant Wall 250 and 299 differ in more than capacity: the 250 fires 53.6 to 240 MBH in a 140 lb chassis with 3-inch venting and 1-1/4-inch water connections, while the 299 fires 72.5 to 299 MBH in a larger 210 lb chassis with 4-inch venting and 1-1/2-inch connections. The 250's lower minimum fire and higher 5.5:1 turndown suit lighter loads.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Ideal Gallant Wall 250 and Ideal Gallant Wall 299
SpecificationIdeal Gallant Wall 250Ideal Gallant Wall 299
Input modulation, minimum (NG & LP)53.6 MBH72.5 MBH
Input modulation, maximum (NG & LP)240 MBH299 MBH
Efficiency95 %95 %
Turndown ratio5.5:14.1:1
AHRI net rating192 MBH242 MBH
DOE heating capacity222 MBH278 MBH
Weight140 lb210 lb
Water volume4.5 gal7.4 gal

What actually separates them

The 250 and 299 are the smaller Gallant Wall models, both heat-only condensing boilers at 95% AFUE with a stainless steel fire-tube heat exchanger, ASME certification and ENERGY STAR listing. The 250 modulates 53.6 to 240 MBH with a 5.5:1 turndown and a 192 MBH AHRI net rating; the 299 modulates 72.5 to 299 MBH with a 4.1:1 turndown and a 242 MBH AHRI net rating.

The chassis step is significant: the 250 measures 19.75 x 36.5625 x 17.3125 inches at 140 lb with 4.5 gallons of water volume, 3/4-inch gas, 1-1/4-inch supply/return and 3-inch vent/air. The 299 grows to 24.875 x 39.375 x 23.625 inches at 210 lb with 7.4 gallons, 1-inch gas, 1-1/2-inch supply/return and 4-inch vent/air.

Both carry the CTRLMax control with four configurable circulator outputs, two reset curves and an integrated cascade function for up to six boilers. In the Gallant Cascade line the 250 forms the CPS500 kit (two boilers, 43.6–480 MBH total input) while the 299 appears in CPS600 and larger configurations.

CurrentCanadian status unknown
Input
53.6–240 MBH
Output (max)
—
AFUE
95 %

The Ideal Gallant Wall 250 is the smallest Gallant model: 53.6 to 240 MBH input at 95% AFUE, 5.5:1 turndown and a 140 lb wall-hung cabinet with 3-inch venting and an integrated six-boiler cascade function.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
72.5–299 MBH
Output (max)
—
AFUE
95 %

The Ideal Gallant Wall 299 is the mid-size Gallant model: 72.5 to 299 MBH input at 95% AFUE with a 4.1:1 turndown, stepping up to the larger 210 lb chassis with 4-inch venting and 1-inch gas.

Natural gasPropaneHeating-only

Frequently asked questions

Which Gallant model has the higher turndown ratio?

The 250, at 5.5:1 against the 299's 4.1:1, with a lower 53.6 MBH minimum input against 72.5 MBH.

What connections does each model use?

The 250: 3/4-inch gas, 1-1/4-inch water and 3-inch vent. The 299: 1-inch gas, 1-1/2-inch water and 4-inch vent, per the official model table.

Can both models be cascaded?

Yes — both list an integrated cascade function for up to six boilers, and both appear in published Gallant Cascade rack kits.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate