Skip to content
Boilers.caby ROMA Heating & Cooling

Ideal Heating · Gallant Wall

Ideal Gallant Wall 299

The Ideal Gallant Wall 299 is the mid-size Gallant model: 72.5 to 299 MBH input at 95% AFUE with a 4.1:1 turndown, stepping up to the larger 210 lb chassis with 4-inch venting and 1-inch gas.

CurrentCanadian status unknown

Key figures

Max input
299 MBH
Max CSA output
AFUE
95 %
Min input
72.5 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Ideal Gallant Wall 299 in practice

The Gallant Wall 299 modulates from 72.5 to 299 MBH input at 95% AFUE, with a 242 MBH AHRI net rating and a 278 MBH DOE heating capacity. Its published turndown is 4.1:1 — lower than the 250 and 399 — but the minimum fire is the same 72.5 MBH as the 399, which matters when sizing a plant that runs at part load for much of the year.

The 299 moves to the larger Gallant chassis: 24.875 x 39.375 x 23.625 inches, 210 lb and 7.4 gallons of water volume, with 1-inch gas, 1-1/2-inch supply/return and 4-inch vent/air connections. It keeps the series' stainless steel fire-tube heat exchanger, ASME certification and ENERGY STAR listing, and the CTRLMax control with four configurable circulator outputs and integrated six-boiler cascade capability.

The model is used in several Gallant Cascade kits, including the CPS800 and larger configurations. Natural-gas (IDGA299) and propane (IDGA299LP) versions are published. No explicit Canadian sales statement was found on the official pages checked on 2026-09-09; the Exalt and Gallant submittals list ANSI Z21.13 and CSA 4.9 compliance, so Boilers.ca records canadianStatus as unknown.

Best suited to

  • Commercial and large residential loads between roughly 240 and 299 MBH
  • Plants planning larger Gallant Cascade racks
  • Projects needing 4-inch venting and 1-1/2-inch water connections

Applicability and support

Model number
IDGA299 (NG) / IDGA299LP (LP)
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Ideal Heating. Units are shown with every value; notes flag conflicting sources or missing figures.

Ideal Gallant Wall 299 specifications
SpecificationValueNote
Input
Input modulation, minimum (NG & LP)72.5 MBHPer the official model table.
Input modulation, maximum (NG & LP)299 MBHPer the official model table.
Output
AHRI net rating242 MBHPer the official model table.
DOE heating capacity278 MBHPer the official model table.
Efficiency
Efficiency95 %95% AFUE per the official model table.
Domestic hot water
Domestic hot waterHeating-only; pair with a separate DHW source
Venting and air
Vent / air diameter4 in
Physical and connections
Weight210 lb
Width24.875 in
Height39.375 in
Depth23.625 in
Operating limits and other
Turndown ratio4.1:1Per the official model table.
Gas connection1 in
Supply / return connections1-1/2 in
Water volume7.4 galPer the official model table.

Frequently asked questions

What is the input range of the Gallant Wall 299?

72.5 to 299 MBH with a 4.1:1 turndown, a 242 MBH AHRI net rating and a 278 MBH DOE heating capacity, at 95% AFUE.

Why is the 299's turndown lower than the 250's?

The official model table prints 4.1:1 for the 299 against 5.5:1 for the 250 and 399, with the same 72.5 MBH minimum input as the 399.

What size connections does the Gallant Wall 299 use?

1-inch gas, 1-1/2-inch supply/return and 4-inch vent/air, per the official model table.

Questions about the Ideal Gallant Wall 299?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate