Ideal Gallant Wall 250 and Ideal Gallant Wall 399 are two condensing boilers from the Ideal Heating Gallant Wall line. Published ratings: Ideal Gallant Wall 250 at 53.6–240 MBH input, 192 MBH AHRI net rating and 95% AFUE; Ideal Gallant Wall 399 at 72.5–399 MBH input, 330 MBH AHRI net rating and 95.1% AFUE. Ideal Gallant Wall 399 lists 159 MBH more input than Ideal Gallant Wall 250 (399 MBH against 240 MBH). Ideal Gallant Wall 399 carries the higher published AFUE at 95.1%, against 95%. Ideal Gallant Wall 399 lists 76 lb more shipping weight than Ideal Gallant Wall 250 (216 lb against 140 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Ideal Gallant Wall 250 and Ideal Gallant Wall 399
SpecificationIdeal Gallant Wall 250Ideal Gallant Wall 399
Input modulation, minimum (NG & LP)53.6 MBH72.5 MBH
Input modulation, maximum (NG & LP)240 MBH399 MBH
Efficiency95 %95.1 %
Turndown ratio5.5:15.5:1
Domestic hot waterHeating-only; pair with a separate DHW sourceHeating-only; pair with a separate DHW source
Weight140 lb216 lb
Height36.563 in39.375 in
Width19.75 in24.875 in
Depth17.313 in23.625 in
Supply / return connections1-1/4 in1-1/2 in
Gas connection3/4 in1 in
AHRI net rating192 MBH330 MBH
DOE heating capacity222 MBH379 MBH
Vent / air diameter3 in4 in
Water volume4.5 gal7.4 gal

What actually separates them

Published ratings: the Ideal Gallant Wall 250 is rated 53.6–240 MBH input, 192 MBH AHRI net rating and 95% AFUE; the Ideal Gallant Wall 399 is rated 72.5–399 MBH input, 330 MBH AHRI net rating and 95.1% AFUE. Ideal Gallant Wall 399 lists 159 MBH more input than Ideal Gallant Wall 250 (399 MBH against 240 MBH). Ideal Gallant Wall 399 carries the higher published AFUE at 95.1%, against 95%.

Ideal Gallant Wall 399 lists 76 lb more shipping weight than Ideal Gallant Wall 250 (216 lb against 140 lb). The height differs: the Ideal Gallant Wall 250 lists 36.5625 in, while the Ideal Gallant Wall 399 lists 39.375 in. The width differs: the Ideal Gallant Wall 250 lists 19.75 in, while the Ideal Gallant Wall 399 lists 24.875 in. The depth differs: the Ideal Gallant Wall 250 lists 17.3125 in, while the Ideal Gallant Wall 399 lists 23.625 in.

Both records print the same turndown (5.5:1) and domestic-hot-water arrangement (Heating-only; pair with a separate DHW source), per the cited sources.

CurrentCanadian status unknown
Input
53.6–240 MBH
Output (max)
—
AFUE
95 %

The Ideal Gallant Wall 250 is the smallest Gallant model: 53.6 to 240 MBH input at 95% AFUE, 5.5:1 turndown and a 140 lb wall-hung cabinet with 3-inch venting and an integrated six-boiler cascade function.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
72.5–399 MBH
Output (max)
—
AFUE
95.1 %

The Ideal Gallant Wall 399 is the largest Gallant model: 72.5 to 399 MBH input with a 5.5:1 turndown, a 330 MBH AHRI net rating and a printed 95.1% figure the page footnotes as thermal efficiency.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The Ideal Gallant Wall 399 lists 399 MBH, against 240 MBH on the Ideal Gallant Wall 250, per the cited documentation.

Which model is more efficient?

The Ideal Gallant Wall 399 carries the higher published AFUE at 95.1%, against 95%.

How much heavier is the Ideal Gallant Wall 399?

It ships at 216 lb against 140 lb for the Ideal Gallant Wall 250, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate