Ideal Gallant Wall 399
The Ideal Gallant Wall 399 is the largest Gallant model: 72.5 to 399 MBH input with a 5.5:1 turndown, a 330 MBH AHRI net rating and a printed 95.1% figure the page footnotes as thermal efficiency.
Key figures
- Max input
- 399 MBH
- Max CSA output
- —
- AFUE
- 95.1 %
- Min input
- 72.5 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Ideal Gallant Wall 399 in practice
The Gallant Wall 399 tops the line at 399 MBH maximum input with a 72.5 MBH minimum — the same minimum as the 299 — and a 5.5:1 turndown, giving it a 330 MBH AHRI net rating and a 379 MBH DOE heating capacity. The page prints 95.1% for this model, footnoted as thermal efficiency, against the 95% AFUE rows on the 250 and 299.
Physically it shares the larger Gallant chassis with the 299: 24.875 x 39.375 x 23.625 inches, 216 lb and 7.4 gallons of water volume, with 1-inch gas, 1-1/2-inch supply/return and 4-inch vent/air connections. It is ASME certified and ENERGY STAR listed and carries the CTRLMax control with four configurable circulator outputs and integrated cascade capability for up to six boilers.
The 399 is the building block for the larger Gallant Cascade kits — CPS1000, CPS1200, CPS1600 and CPS2000 — where 3 to 5 boilers reach total inputs up to 1,995 MBH. Natural-gas (IDGA399) and propane (IDGA399LP) versions are published. No explicit Canadian sales statement was found on the official pages checked on 2026-09-09; the Exalt and Gallant submittals list ANSI Z21.13 and CSA 4.9 compliance, so Boilers.ca records canadianStatus as unknown.
Best suited to
- The largest single-boiler loads in the Gallant line, up to 399 MBH
- Gallant Cascade CPS1000 through CPS2000 rack configurations
- Projects wanting the series' highest printed efficiency figure
Applicability and support
- Model number
- IDGA399 (NG) / IDGA399LP (LP)
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Ideal Heating. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input modulation, minimum (NG & LP) | 72.5 MBH | Per the official model table. |
| Input modulation, maximum (NG & LP) | 399 MBH | Per the official model table. |
| Output | ||
| AHRI net rating | 330 MBH | Per the official model table. |
| DOE heating capacity | 379 MBH | Per the official model table. |
| Efficiency | ||
| Efficiency | 95.1 % | 95.1% printed for this model and footnoted on the page as thermal efficiency. |
| Domestic hot water | ||
| Domestic hot water | Heating-only; pair with a separate DHW source | |
| Venting and air | ||
| Vent / air diameter | 4 in | |
| Physical and connections | ||
| Weight | 216 lb | |
| Width | 24.875 in | |
| Height | 39.375 in | |
| Depth | 23.625 in | |
| Operating limits and other | ||
| Turndown ratio | 5.5:1 | Per the official model table. |
| Gas connection | 1 in | |
| Supply / return connections | 1-1/2 in | |
| Water volume | 7.4 gal | Per the official model table. |
Manuals
Frequently asked questions
What efficiency does the Gallant Wall 399 print?
The model table prints 95.1% for the 399, with a page footnote identifying it as thermal efficiency; the 250 and 299 rows print 95% AFUE.
What is the firing range of the Gallant Wall 399?
72.5 to 399 MBH with a 5.5:1 turndown, a 330 MBH AHRI net rating and a 379 MBH DOE heating capacity.
Which cascade kits use the Gallant 399?
The CPS1000 (three 399s), CPS1200 (three 399s), CPS1600 (four 399s) and CPS2000 (five 399s) rack configurations, with total inputs up to 1,995 MBH.
Questions about the Ideal Gallant Wall 399?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Ideal Heating NA — Gallant Wall product page and model table · accessed September 9, 2026
- Ideal Heating NA — Gallant 399 engineering submittal (2023-29) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.