Lochinvar Crest FBN2501 vs FBN3001

Verdict in brief

The Crest FBN2501 and FBN3001 both run 20:1 turndown on 4" pipe with a 2" gas inlet, but the 3001 fires 150 to 3000 MBH (2883 MBH gross), steps air and vent to 10", and prints a 3,900 lb weight with water against the 2501's 3,600.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Crest FBN2501 and Lochinvar Crest FBN3001
SpecificationLochinvar Crest FBN2501Lochinvar Crest FBN3001
Heating input, minimum125 MBH150 MBH
Heating input, maximum2,500 MBH3,000 MBH
Gross output2,400 MBH2,883 MBH
Net AHRI water rating2,087 MBH2,507 MBH
Water content157 gal156 gal
Pipe outlet connection4"4"
Pipe inlet connection4"4"
Gas connection2"2"
Air size8"10"
Vent size9"10"
Weight with water3,600 lb3,900 lb

What actually separates them

Both sit in the 2501-3501 band the I&O rates at 20:1 turndown, sharing the 4" pipe outlet and inlet and 2" gas inlet, and both keep minimum fires low enough for real part-load operation (125 MBH and 150 MBH).

The 3001 adds 500 MBH of ceiling: maximum input rises from 2500 to 3000 MBH, gross output from 2400 to 2883 MBH and the AHRI net rating from 2087 to 2507 MBH.

The air and vent both step to 10" per the ratings table at the 3001 (against 8" air and 9" vent on the 2501), while water content stays nearly flat at 156-157 gallons and weight with water grows from 3,600 to 3,900 lb. Both vent to 100 equivalent feet on the wave fire-tube platform.

CurrentSold in Canada
Input
125–2500 MBH
Output (max)
—
AFUE
—

The Crest FBN2501 fires 125 to 2500 MBH with 2400 MBH gross output and a 2087 MBH AHRI net rating at 20:1 turndown, stepping the gas inlet to 2" with a 9" vent.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
150–3000 MBH
Output (max)
—
AFUE
—

The Crest FBN3001 fires 150 to 3000 MBH with 2883 MBH gross output and a 2507 MBH AHRI net rating at 20:1 turndown, stepping air and vent to 10" at a 3.0 million BTU/hr ceiling.

Natural gasPropaneHeating-only

Frequently asked questions

What changes at the FBN3001?

Maximum input rises from 2500 to 3000 MBH and air and vent step from 8"/9" to 10"/10"; the 4" pipe and 2" gas inlet are unchanged, and turndown stays 20:1.

Which size has more water content?

They are nearly equal — 157 gallons on the 2501 and 156 on the 3001 — despite the 3001 being the larger boiler; its weight with water rises to 3,900 lb.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.