Lochinvar Crest FCB2000 vs FCB2500

Verdict in brief

The Crest with Hellcat FCB2500 opens the FCB sizes Lochinvar's page copy rates at 20:1 turndown: against the FCB2000 it fires 125 to 2500 MBH with 2400 MBH gross output, steps the gas inlet to 2" and the vent to 9", and grows water content from 111 to 157 gallons.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Crest FCB2000 and Lochinvar Crest FCB2500
SpecificationLochinvar Crest FCB2000Lochinvar Crest FCB2500
Heating input, minimum80 MBH125 MBH
Heating input, maximum1,999 MBH2,500 MBH
Gross output1,923 MBH2,400 MBH
Net AHRI water rating1,699 MBH2,087 MBH
Water content111 gal157 gal
Pipe outlet connection4"4"
Pipe inlet connection4"4"
Gas connection1-1/2"2"
Air size8"8"
Vent size8"9"
Weight with water2,570 lb3,600 lb

What actually separates them

Lochinvar's Hellcat page copy states 20:1 turndown for the FCB2500-6000 sizes, while the smaller FCB sizes carry higher minimum fires relative to their ceilings; the ratings table shows the step: 80 MBH minimum on the 2000 against 125 MBH on the 2500.

Maximum input rises from 1999 to 2500 MBH with gross output from 1923 to 2400 MBH and the AHRI net rating from 1699 to 2087 MBH. Water content jumps from 111 to 157 gallons and weight with water from 2,570 to 3,600 lb.

The connections step at the 2500: the gas inlet grows from 1-1/2" to 2" and the ratings table prints an 8" air size with a 9" vent, against 8"/8" on the 2000. Both vent to 150 equivalent feet with the Hellcat combustion system.

CurrentSold in Canada
Input
80–1999 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB2000 fires 80 to 1999 MBH with 1923 MBH gross output and a 1699 MBH AHRI net rating, keeping 4" pipe and 8" air and vent at the top of the small FCB sizes.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
125–2500 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB2500 fires 125 to 2500 MBH with 2400 MBH gross output and a 2087 MBH AHRI net rating — the entry of the FCB sizes Lochinvar's page copy rates at 20:1 turndown.

Natural gasPropaneHeating-only

Frequently asked questions

What turndown does the FCB2500 have?

Lochinvar's page copy rates the FCB2500-6000 sizes at 20:1 turndown; the FCB2000 sits below that band with a minimum fire of 80 MBH on a 1999 MBH maximum.

What changes at the FCB2500?

Maximum input rises from 1999 to 2500 MBH, the gas inlet from 1-1/2" to 2", the vent from 8" to 9", and water content from 111 to 157 gallons.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.