Lochinvar · Crest (FB / Hellcat FCB)
Lochinvar Crest FCB2500
The Crest with Hellcat FCB2500 fires 125 to 2500 MBH with 2400 MBH gross output and a 2087 MBH AHRI net rating — the entry of the FCB sizes Lochinvar's page copy rates at 20:1 turndown.
Key figures
- Max input
- 2,500 MBH
- Max CSA output
- —
- AFUE
- —
- Min input
- 125 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Lochinvar Crest FCB2500 in practice
The FCB2500 opens the upper half of the Crest with Hellcat range at 2.5 million BTU/hr: the I&O ratings table lists 125 to 2500 MBH input with 2400 MBH gross output and a 2087 MBH AHRI net water rating. Lochinvar's Hellcat page copy states 20:1 turndown for the FCB2500-6000 sizes, and the FCB4000N page's feature copy carries the same claim for the line.
Connections follow the FB2501 pattern — 4" pipe outlet and inlet, a 2" gas inlet and an 8" air size with a 9" vent — with water content at 157 gallons and weight with water at 3,600 lb per the ratings table. RealTime O2 Trim combustion, the 10" capacitive touchscreen and venting to 150 equivalent feet in stainless steel, polypropylene, PVC or CPVC complete the Hellcat package.
Best suited to
- Central plants entering the 20:1-turndown band of the FCB line at 2.5 million BTU/hr
- Projects stepping to a 2" gas connection with 4" boiler piping
- Plants that want Hellcat combustion at the FCB2500's specific air/vent sizes
Applicability and support
- Model number
- FCB2500
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 125 MBH | Per the I&O ratings table. |
| Heating input, maximum | 2,500 MBH | Per the I&O ratings table. |
| Output | ||
| Gross output | 2,400 MBH | Per the I&O ratings table. |
| Net AHRI water rating | 2,087 MBH | Per the I&O ratings table. |
| Venting and air | ||
| Air size | 8" | Per the I&O ratings table. |
| Vent size | 9" | Per the I&O ratings table. |
| Venting | Category IV sealed combustion; room air/direct vent/common vent in stainless steel, polypropylene, PVC or CPVC | Up to 150 equivalent feet per the Crest with Hellcat product-page feature list. |
| Physical and connections | ||
| Water content | 157 gal | Per the I&O ratings table. |
| Pipe outlet connection | 4" | Per the I&O ratings table. |
| Pipe inlet connection | 4" | Per the I&O ratings table. |
| Gas connection | 2" | Per the I&O ratings table. |
| Weight with water | 3,600 lb | Per the I&O ratings table. |
Manuals
Alerts documented for this model
- Gas Pressure SW Open
- Low Water Cutoff Open
- Blocked Drain SW Open
- APS Open
- Anti-cycling
- Flame Failure
- Flame Fail Running
- Gas Valve / Relay Failure
- Auto Reset High Limit
- Manual Reset High Limit Open
- Fan Speed Low
- Fan Speed High
- Louver Proving Sw Open
- Flue Temp High
- Delta T High
- Outlet Temp High
- Parameter Programming Complete
- Sensor Open
- Sensor Shorted
- Flue Sensor Open
- Flue Sensor Shorted
- Too Many Resets - Try Later
- Internal Fault
- Flue Temp Shutdown
- Delta T Shutdown
- Outlet Temp Shutdown
- Writing/Programming EEProm Error
- CRC Parameter Error
- Wrong Error Code
- Flame Sense Out of Sequence 1
- Flame Sense Out of Sequence 2
- Flue Damper Switch Open
- IO Expander Out Error
- Failure ADC Controller
- Outlet Sensor Differential
- Flue Sensor Differential
Frequently asked questions
What are the FCB2500's ratings?
125 to 2500 MBH of input with 2400 MBH gross output and a 2087 MBH AHRI net water rating per the I&O ratings table.
What turndown does Lochinvar claim for the FCB2500?
The Hellcat page copy states 20:1 turndown for the FCB2500-6000 sizes; the FCB4000N product page prints the 20:1 headline for the line.
Questions about the Lochinvar Crest FCB2500?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Lochinvar Crest FCB2000 vs FCB2500Comparison
- Lochinvar Crest FBN0751Same series
- Lochinvar Crest FBN1001Same series
- Lochinvar Crest FBN1251Same series
- Lochinvar Crest FBN1501Same series
- Lochinvar Crest FBN1751Same series
- Lochinvar Crest FBN2001Same series
- Lochinvar Crest FBN2501Same series
- Lochinvar Crest FBN3001Same series
- Lochinvar Crest FBN3501Same series
- Lochinvar Crest FBN4001Same series
- Lochinvar Crest FBN5001Same series
- Lochinvar Crest FBN6001Same series
- Lochinvar Crest FCB1000Same series
- Lochinvar Crest FCB1500Same series
- Lochinvar Crest FCB2000Same series
- Lochinvar Crest FCB3000Same series
- Lochinvar Crest FCB4000Same series
- Lochinvar Crest FCB5000Same series
- Lochinvar Crest FCB6000Same series
- Crest (FB / Hellcat FCB) series hub
- Buying guide
Sources and verification
- Lochinvar — Crest with Hellcat (FCB4000N) model page · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.