Lochinvar Crest FCB2000

The Crest with Hellcat FCB2000 fires 80 to 1999 MBH with 1923 MBH gross output and a 1699 MBH AHRI net rating, keeping 4" pipe and 8" air and vent at the top of the small FCB sizes.

CurrentSold in Canada

Key figures

Max input
1,999 MBH
Max CSA output
—
AFUE
—
Min input
80 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Crest FCB2000 in practice

The FCB2000 closes the small half of the Crest with Hellcat range at a nominal 2.0 million BTU/hr: the I&O ratings table lists 80 to 1999 MBH input with 1923 MBH gross output and a 1699 MBH AHRI net water rating. Connections continue the FCB1500's pattern — 4" pipe outlet and inlet, a 1-1/2" gas inlet and 8" air and vent — with water content growing to 111 gallons.

Weight with water is 2,570 lb per the ratings table. The Hellcat combustion system with RealTime O2 Trim, the full-color 10" capacitive touchscreen and room air/direct vent or common vent capability in stainless steel, polypropylene, PVC or CPVC to 150 equivalent feet set the FCB line apart from the FB-generation Crest.

Best suited to

  • Commercial loads approaching 2.0 million BTU/hr on the Hellcat platform
  • Projects that keep 4" piping through a 1999 MBH ceiling
  • Designs preferring the FCB's common-vent capability to 150 equivalent feet

Applicability and support

Model number
FCB2000
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Crest FCB2000 specifications
SpecificationValueNote
Input
Heating input, minimum80 MBHPer the I&O ratings table.
Heating input, maximum1,999 MBHPer the I&O ratings table.
Output
Gross output1,923 MBHPer the I&O ratings table.
Net AHRI water rating1,699 MBHPer the I&O ratings table.
Venting and air
Air size8"Per the I&O ratings table.
Vent size8"Per the I&O ratings table.
VentingCategory IV sealed combustion; room air/direct vent/common vent in stainless steel, polypropylene, PVC or CPVCUp to 150 equivalent feet per the Crest with Hellcat product-page feature list.
Physical and connections
Water content111 galPer the I&O ratings table.
Pipe outlet connection4"Per the I&O ratings table.
Pipe inlet connection4"Per the I&O ratings table.
Gas connection1-1/2"Per the I&O ratings table.
Weight with water2,570 lbPer the I&O ratings table.

Frequently asked questions

What are the FCB2000's ratings?

80 to 1999 MBH of input with 1923 MBH gross output and a 1699 MBH AHRI net water rating per the I&O ratings table.

What connections does the FCB2000 use?

4" pipe outlet and inlet, a 1-1/2" gas inlet and 8" air and vent sizes, with a 111-gallon water content and 2,570 lb weight with water per the ratings table.

Questions about the Lochinvar Crest FCB2000?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.