Lochinvar Crest FCB3000 vs FCB4000

Verdict in brief

The Crest with Hellcat FCB3000 and FCB4000 split at the 4.0 million BTU/hr mark: the 4000 fires 200 to 3999 MBH with 3843 MBH gross output, steps the gas inlet to 2-1/2" and air/vent to 12", and is the Hellcat size whose page prints 96.0% thermal efficiency.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Crest FCB3000 and Lochinvar Crest FCB4000
SpecificationLochinvar Crest FCB3000Lochinvar Crest FCB4000
Heating input, minimum150 MBH200 MBH
Heating input, maximum3,000 MBH3,999 MBH
Gross output2,883 MBH3,843 MBH
Net AHRI water rating2,507 MBH3,342 MBH
Water content156 gal201 gal
Pipe outlet connection4"4"
Pipe inlet connection4"4"
Gas connection2"2-1/2"
Air size10"12"
Vent size10"12"
Weight with water3,900 lb5,200 lb

What actually separates them

Both sit in the 20:1-turndown band the Hellcat page copy applies to the FCB2500-6000 sizes, sharing the 4" pipe outlet and inlet and the RealTime O2 Trim combustion system with the 10" capacitive touchscreen.

The 4000 adds 999 MBH of ceiling: maximum input rises from 3000 to 3999 MBH with gross output from 2883 to 3843 MBH and the AHRI net rating from 2507 to 3342 MBH. The gas inlet steps from 2" to 2-1/2" and air and vent from 10" to 12".

The FCB4000 is the documentation size for the Hellcat line: its product page headlines 96.0% thermal efficiency (spec block 96%), lists an ASME H stamp, 480 V service and a 3,874 lb shipping weight, and its ratings row prints 200 MBH minimum input with 201 gallons of water.

CurrentSold in Canada
Input
150–3000 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB3000 fires 150 to 3000 MBH with 2883 MBH gross output and a 2507 MBH AHRI net rating, stepping air and vent to 10" on the Hellcat platform.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
200–3999 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB4000 fires 200 to 3999 MBH with 3843 MBH gross output and a 3342 MBH AHRI net rating at 96% thermal efficiency per its product page, with 12" air and vent.

Natural gasPropaneHeating-only

Frequently asked questions

What is the FCB4000's efficiency rating?

The FCB4000N product page headlines 96.0% thermal efficiency and its spec block prints 96%. Boilers.ca does not extend that page-level figure to other FCB sizes.

What changes in the plant at the FCB4000?

The gas inlet steps from 2" to 2-1/2" and air and vent from 10" to 12"; the 4" pipe connections stay, and water content grows from 156 to 201 gallons.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.