Lochinvar Crest FCB3000

The Crest with Hellcat FCB3000 fires 150 to 3000 MBH with 2883 MBH gross output and a 2507 MBH AHRI net rating, stepping air and vent to 10" on the Hellcat platform.

CurrentSold in Canada

Key figures

Max input
3,000 MBH
Max CSA output
—
AFUE
—
Min input
150 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Crest FCB3000 in practice

The FCB3000 lifts the Crest with Hellcat range to 3.0 million BTU/hr: the I&O ratings table lists 150 to 3000 MBH input with 2883 MBH gross output and a 2507 MBH AHRI net water rating. It is among the FCB2500-6000 sizes the page copy rates at 20:1 turndown, and the 156-gallon water content sits on the continuing 4" pipe outlet and inlet with a 2" gas inlet.

Air and vent both step to 10" per the ratings table, and weight with water is 3,900 lb. The Hellcat combustion system with RealTime O2 Trim, the 10" capacitive touchscreen control and common-vent capability in stainless steel, polypropylene, PVC or CPVC to 150 equivalent feet define the platform, with voltages to 480 listed for the FCB line's larger sizes per the product page.

Best suited to

  • Commercial and institutional loads near 3.0 million BTU/hr on Hellcat
  • Plants planned around 10" air and vent openings
  • Systems that want 20:1 turndown with O2 trim at the 3000 size

Applicability and support

Model number
FCB3000
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Crest FCB3000 specifications
SpecificationValueNote
Input
Heating input, minimum150 MBHPer the I&O ratings table.
Heating input, maximum3,000 MBHPer the I&O ratings table.
Output
Gross output2,883 MBHPer the I&O ratings table.
Net AHRI water rating2,507 MBHPer the I&O ratings table.
Venting and air
Air size10"Per the I&O ratings table.
Vent size10"Per the I&O ratings table.
VentingCategory IV sealed combustion; room air/direct vent/common vent in stainless steel, polypropylene, PVC or CPVCUp to 150 equivalent feet per the Crest with Hellcat product-page feature list.
Physical and connections
Water content156 galPer the I&O ratings table.
Pipe outlet connection4"Per the I&O ratings table.
Pipe inlet connection4"Per the I&O ratings table.
Gas connection2"Per the I&O ratings table.
Weight with water3,900 lbPer the I&O ratings table.

Frequently asked questions

What are the FCB3000's ratings?

150 to 3000 MBH of input with 2883 MBH gross output and a 2507 MBH AHRI net water rating per the I&O ratings table.

How does the FCB3000 differ from the FCB2500?

Maximum input rises from 2500 to 3000 MBH, air and vent grow from 8"/9" to 10"/10", and weight with water rises from 3,600 to 3,900 lb; pipe and gas connections are unchanged.

Questions about the Lochinvar Crest FCB3000?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate