Lochinvar Knight WHB085 vs WHB110

Verdict in brief

The Knight WHB085 and WHB110 both deliver 95% AFUE on 1" connections, but the 110 lifts the ceiling from 85 to 110 MBH (102 MBH DOE capacity), raises the minimum fire from 8.5 to 11 MBH and shortens the 2" vent allowance from 50 to 40 equivalent feet.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Knight WHB085 and Lochinvar Knight WHB110
SpecificationLochinvar Knight WHB085Lochinvar Knight WHB110
Heating input, minimum8.5 MBH11 MBH
Heating input, maximum85 MBH110 MBH
DOE heating capacity79 MBH102 MBH
AHRI net water rating69 MBH89 MBH
Efficiency (AFUE)95 %95 %
Water content2.2 gal2.3 gal
Space-heating water connections1"1"
Gas connection1/2"1/2"
Max. equivalent vent/air length, 2"50 ft40 ft
Max. equivalent vent/air length, 3"100 ft100 ft
vent-max-4——
Domestic hot waterHeating-only boilerHeating-only boiler

What actually separates them

Both are wall-hung heating-only Knights at 95% AFUE with 1" water connections, a 1/2" gas connection and roughly 2.2-2.3 gallons of water content, and both rely on an indirect tank such as the Squire for domestic hot water.

The 110 adds 25 MBH of maximum input and takes DOE capacity from 79 to 102 MBH, which is the headroom a heat-loss calculation near 100 MBH needs. Its minimum fire rises to 11 MBH, the first step off the 8 MBH floor in the series, so very low-load homes track mild weather better on the 085.

Venting differs at the margins: the 085 allows 2" to 50 equivalent feet while the 110 allows only 40 in 2", and both reach 100 in 3". Neither difference is large; the load calculation drives the choice.

CurrentSold in Canada
Input
8.5–85 MBH
Output (max)
—
AFUE
95 %

The Knight WHB085 steps the wall-hung Knight to 8.5 to 85 MBH input at 95% AFUE, with 79 MBH DOE capacity and a 2.2-gallon water content in the same 1"-connection cabinet family.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
—
AFUE
95 %

The Knight WHB110 is the mid-size wall-hung Knight: 11 to 110 MBH input at 95% AFUE with 102 MBH DOE heating capacity, and 2" venting limited to 40 equivalent feet.

Natural gasPropaneHeating-only

Frequently asked questions

Which Knight has the lower minimum fire?

The WHB085 fires down to 8.5 MBH against the WHB110's 11 MBH. In a home whose load sits well under the boiler's ceiling, the lower minimum means steadier part-load running in mild weather.

Is the WHB110's extra capacity worth it?

Only if the room-by-room heat-loss calculation approaches 110 MBH on a design day. If the load stays under 85 MBH, the 085 delivers the same efficiency at a lower ceiling.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.