Lochinvar Knight WHB155 vs WHB199

Verdict in brief

The Knight WHB155 and WHB199 are the two mid-large wall-hung Knights and share 3"-only venting to 100 equivalent feet, but the 199 fires 44 MBH higher (199 versus 155) with 183 MBH of DOE capacity, steps up to 1-1/4" water connections and holds 5.2 gallons against 3.2.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Knight WHB155 and Lochinvar Knight WHB199
SpecificationLochinvar Knight WHB155Lochinvar Knight WHB199
Heating input, minimum15.5 MBH19.9 MBH
Heating input, maximum155 MBH199 MBH
DOE heating capacity144 MBH183 MBH
AHRI net water rating125 MBH159 MBH
Efficiency (AFUE)95 %95 %
Water content3.2 gal5.2 gal
Space-heating water connections1"1-1/4"
Gas connection1/2"1/2"
vent-max-2
Max. equivalent vent/air length, 3"100 ft100 ft
vent-max-4
Domestic hot waterHeating-only boilerHeating-only boiler

What actually separates them

Both models are 95% AFUE heating-only Knights on the SMART SYSTEM, venting in 3" pipe to 100 equivalent feet with a 1/2" gas connection. Domestic hot water comes from an indirect tank such as Lochinvar's Squire on both.

The 199's ratings step up across the board: maximum input rises from 155 to 199 MBH, DOE capacity from 144 to 183 MBH and the AHRI net rating from 125 to 159 MBH. Minimum fire also rises, from 15.5 to 19.9 MBH.

The 199 is the first wall Knight to need 1-1/4" water connections, and its 5.2-gallon water content reflects the larger heat exchanger. Near-boiler piping must step up to match, which is a planning difference on site rather than a problem.

CurrentSold in Canada
Input
15.5–155 MBH
Output (max)
AFUE
95 %

The Knight WHB155 reaches 15.5 to 155 MBH input at 95% AFUE with 144 MBH DOE capacity, and from this size upward the Knight vents in 3" pipe only.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
AFUE
95 %

The Knight WHB199 is the 199 MBH wall-hung Knight: 19.9 to 199 MBH input at 95% AFUE, stepping up to 1 1/4" water connections and 3" venting to 100 equivalent feet.

Natural gasPropaneHeating-only

Frequently asked questions

Do the WHB155 and WHB199 vent the same way?

Yes — both are 3"-only to 100 equivalent feet per the I&O manual. The 2" option ended at the 110 size.

What changes in the piping at the WHB199?

Water connections step from 1" to 1-1/4" and water content from 3.2 to 5.2 gallons; the gas connection stays 1/2". Near-boiler piping must be sized for the larger fittings.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.