Lochinvar · Knight Wall Mount (WHB)
Lochinvar Knight WHB155
The Knight WHB155 reaches 15.5 to 155 MBH input at 95% AFUE with 144 MBH DOE capacity, and from this size upward the Knight vents in 3" pipe only.
Key figures
- Max input
- 155 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 15.5 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Lochinvar Knight WHB155 in practice
The WHB155 is the first wall Knight that steps up both the input and the venting: it fires 15.5 to 155 MBH, delivers 144 MBH of DOE heating capacity and a 125 MBH AHRI net rating, and from the 155 upward the I&O ratings table lists 3" venting only. Its water content grows to 3.2 gallons.
Heating connections stay at 1" with a 1/2" gas connection, and the boiler remains heating-only with domestic hot water from an indirect tank such as Lochinvar's Squire. The 3" venting-only rule is the practical constraint for retrofits: a long existing 2" run cannot be reused on this size.
Best suited to
- Larger detached homes whose heat-loss calculation approaches 150 MBH
- Projects with radiator systems or several heating zones
- Homes that can commit to 3" venting to 100 equivalent feet
Applicability and support
- Model number
- WHB155L
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 15.5 MBH | Per the I&O ratings table. |
| Heating input, maximum | 155 MBH | Per the I&O ratings table. |
| Output | ||
| DOE heating capacity | 144 MBH | DOE heating capacity per the I&O ratings table. |
| AHRI net water rating | 125 MBH | Net AHRI rating based on a piping and pickup allowance of 1.15. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95% AFUE per the I&O ratings table. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler | Pairs with the Squire indirect water heater or another indirect tank; the Knight is heating-only. |
| Venting and air | ||
| Venting | Category IV sealed combustion; PVC, CPVC, polypropylene or stainless steel | In Canada, plastic venting must be a ULC S636-certified system. |
| Max. equivalent vent/air length, 3" | 100 ft | Table 3D (air intake/vent piping sizes), I&O manual. |
| Physical and connections | ||
| Water content | 3.2 gal | Per the I&O ratings table. |
| Space-heating water connections | 1" | Per the I&O ratings table. |
| Gas connection | 1/2" | Per the I&O ratings table. |
Manuals
Alerts documented for this model
- Gas Pressure SW
- Flow Switch/LWCO
- Air Pressure SW
- Too Many Recyclings
- Anti-cycling
- Flame Fail Ign
- Flame Sequence
- Outlet ARHL
- Outlet MRHL
- Fan Speed
- Inlet, Outlet, or Flue Sensor Fault
- AUX Contact Sw
- Outlet Temp Diff
- Fatal Error
- Memory Error
- Flue Temp High / Flue Temp Limit
- Delta T High / Delta T Limit
- Outlet Temp High / Outlet Temp Limit
- Low 24 vac
- Watch Dog Error
- Write EEProm
- CRC Parameters
- No Error Stored
Frequently asked questions
Why is the WHB155 venting 3" only?
The I&O ratings table and its Table 3D venting sizes list 3" pipe for the 155 and 199 sizes, with a 100 equivalent foot maximum. The 2" option ends at the 110 size.
What are the WHB155's ratings?
15.5 to 155 MBH input, 144 MBH DOE heating capacity and a 125 MBH AHRI net water rating at 95% AFUE, per the I&O ratings table.
Questions about the Lochinvar Knight WHB155?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Lochinvar Knight WHB110 vs WHB155Comparison
- Lochinvar Knight WHB155 vs WHB199Comparison
- Weil-McLain ECO Tec 150-H vs Lochinvar Knight WHB155Comparison
- Lochinvar Knight WHB055Same series
- Lochinvar Knight WHB085Same series
- Lochinvar Knight WHB110Same series
- Lochinvar Knight WHB199Same series
- Lochinvar Knight WHB285Same series
- Lochinvar Knight WHB399Same series
- Knight Wall Mount (WHB) series hub
- Buying guide
Sources and verification
- Lochinvar — Knight Fire Tube Wall Mount (WHB055L) model page · accessed September 7, 2026
- Knight Wall Hung Fire Tube (WHB055-399) I&O Manual, Rev T · Rev T · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.