Navien NCB-190/060H vs NCB-190/080H

Verdict in brief

The NCB-190/060H and NCB-190/080H are the two smallest NCB-H combis and are twins below the maximum: both fire down to 11 MBH, weigh 87 lb in the same 17.3 x 29.3 x 12.8 in cabinet, draw up to 160,000 BTU/h for DHW and are rated 95.0% AFUE. The 080H adds 20 MBH of heating ceiling (80 versus 60 MBH), so a heat-loss calculation decides which one the home needs.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Navien NCB-190/060H and Navien NCB-190/080H
SpecificationNavien NCB-190/060HNavien NCB-190/080H
Heating input, minimum11 MBH11 MBH
Heating input, maximum60 MBH80 MBH
DHW input, maximum160 MBH160 MBH
Efficiency (AFUE)95 %95 %
Weight87 lb87 lb
Max. equivalent vent length, 2"65 ft65 ft
Max. equivalent vent length, 3"150 ft150 ft
Domestic hot waterIntegrated in the combi heat exchangerIntegrated in the combi heat exchanger

What actually separates them

Both models are the same physical unit: an 87 lb wall-hung combi in the 17.3 x 29.3 x 12.8 in NCB-H cabinet, rated 95.0% AFUE, with Navien's dual stainless steel heat exchanger arrangement and a built-in DHW module that fires up to 160,000 BTU/h.

Minimum fire is identical at 11 MBH, so in a low-load home the two boilers behave the same during mild weather. The only published difference is the heating ceiling: 60 MBH on the 060H against 80 MBH on the 080H.

Venting and connections match exactly — 2" to 65 equivalent feet or 3" to 150, 1" NPT heating connections and a 3/4" NPT gas connection. The choice therefore reduces to the room-by-room heat-loss calculation: if the load never approaches 60 MBH the smaller model is sufficient, and if it does the 080H provides headroom with no footprint penalty.

CurrentSold in Canada
Input
11–60 MBH
Output (max)
AFUE
95 %

The Navien NCB-190/060H is the smallest NCB-H combi: 11 to 60 MBH space-heating input with DHW input to 160,000 BTU/h in one wall-hung condensing appliance, rated 95.0% AFUE and weighing 87 lb.

Natural gasPropaneCombi
CurrentSold in Canada
Input
11–80 MBH
Output (max)
AFUE
95 %

The Navien NCB-190/080H steps the NCB-H combi up to 11 to 80 MBH heating input with the same 160,000 BTU/h DHW input as the 060H, rated 95.0% AFUE in the identical 87 lb cabinet.

Natural gasPropaneCombi

Frequently asked questions

Are the NCB-190/060H and NCB-190/080H the same size?

Yes. Both weigh 87 lb and measure 17.3 x 29.3 x 12.8 in, with the same 11 MBH minimum fire and the same 160,000 BTU/h DHW input.

When does the 080H make more sense than the 060H?

When the heat-loss calculation shows the home needs more than the 060H's 60 MBH heating ceiling on a design day. Extra ceiling without a matching load is not an advantage.

Do both models heat domestic water the same way?

Yes. Both are NCB-H combis: domestic hot water is produced on demand in the built-in DHW module, so no separate tank is needed.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate