Navien NCB-190/060H
The Navien NCB-190/060H is the smallest NCB-H combi: 11 to 60 MBH space-heating input with DHW input to 160,000 BTU/h in one wall-hung condensing appliance, rated 95.0% AFUE and weighing 87 lb.
Key figures
- Max input
- 60 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 11 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Navien NCB-190/060H in practice
The NCB-190/060H heats from 11 to 60 MBH input while its built-in DHW module fires up to 160,000 BTU/h for on-demand hot water, which is the pattern of every NCB-H: the DHW side is rated well above the heating side. It is the smallest of the five NCB-H models and suits homes whose heat-loss calculation lands well below 60 MBH, leaving most of the appliance's capability to domestic hot water.
Navien builds the combi around a primary stainless steel heating heat exchanger and a secondary stainless steel DHW unit, and the installation manual rates the whole line at 95.0% AFUE. At 87 lb and 17.3 x 29.3 x 12.8 in it shares the compact cabinet of the NCB-190/080H, and it vents in 2" PVC, CPVC or approved polypropylene to 65 equivalent feet or 3" to 150.
Best suited to
- Compact homes and townhouses whose heat-loss calculation fits under 60 MBH
- Households wanting on-demand hot water without a separate tank
- Tight mechanical rooms where the 17.3 x 12.8 in footprint and 87 lb weight keep installation simple
Applicability and support
- Model number
- NCB-190/060H
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Navien. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 11 MBH | Space-heating input. |
| Heating input, maximum | 60 MBH | Space-heating input. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the installation manual. |
| Domestic hot water | ||
| DHW input, minimum | 10.7 MBH | 10,700 BTU/h |
| DHW input, maximum | 160 MBH | 160,000 BTU/h |
| Domestic hot water | Integrated in the combi heat exchanger | |
| Venting and air | ||
| Venting | PVC, CPVC or approved polypropylene; 2" or 3" | Canada: plastic venting must meet ULC S636 where required. |
| Max. equivalent vent length, 2" | 65 ft | |
| Max. equivalent vent length, 3" | 150 ft | |
| Physical and connections | ||
| Weight | 87 lb | Empty; per the installation manual. |
| Width | 17.3 in | |
| Height | 29.3 in | |
| Depth | 12.8 in | |
| Gas connection | 3/4" NPT | |
| Heating water connections | 1" NPT | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Separate Navien ratings per fuel. |
| Altitude rating | 10,100 ft | Per installation manual. |
| System water pressure | 12 – 30 psi | |
Manuals
Alerts documented for this model
Frequently asked questions
Is 60 MBH of heating input enough for my house?
A room-by-room heat-loss calculation decides that, not floor area. The NCB-190/060H caps space heating at 60 MBH input while firing up to 160,000 BTU/h for domestic hot water, so it suits homes whose heating load fits below that ceiling.
Does the NCB-190/060H run on propane?
Yes. Navien lists the NCB-H series for natural gas or propane and publishes separate ratings per fuel; fuel setup is a gas-fitting task for a licensed contractor.
Can I vent the NCB-190/060H in 2" pipe?
Yes, to a maximum of 65 equivalent feet in 2". In 3" pipe the installation manual allows up to 150 equivalent feet.
Questions about the Navien NCB-190/060H?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Navien Canada — NCB-H series · accessed September 7, 2026
- NCB-H Installation and Operation Manual (EN) · accessed September 7, 2026
- NCB-H Service Manual, Ver 1.00 (Feb 2021) · Ver 1.00 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.