Navien
Navien NCB-190/080H
- Input
- 11–80 MBH
- Output (max)
- —
- AFUE
- 95 %
The Navien NCB-190/080H steps the NCB-H combi up to 11 to 80 MBH heating input with the same 160,000 BTU/h DHW input as the 060H, rated 95.0% AFUE in the identical 87 lb cabinet.
Canada-wide gas boiler information · On-site service in Greater Vancouver, BC
Boilers.ca is a brand of ROMA Heating & Cooling · Licensed gas contractor LGA0202903
Comparison
Verdict in brief
Moving from the NCB-190/080H to the NCB-240/110H raises the heating ceiling from 80 to 110 MBH and the DHW input from 160,000 to 199,900 BTU/h, at the cost of a higher minimum fire (13 versus 11 MBH) and a 9 lb weight gain (96 versus 87 lb) in the same cabinet.
Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.
| Specification | Navien NCB-190/080H | Navien NCB-240/110H |
|---|---|---|
| Heating input, minimum | 11 MBH | 13 MBH |
| Heating input, maximum | 80 MBH | 110 MBH |
| DHW input, maximum | 160 MBH | 199.9 MBH |
| Efficiency (AFUE) | 95 % | 95 % |
| Weight | 87 lb | 96 lb |
| Max. equivalent vent length, 2" | 65 ft | 65 ft |
| Max. equivalent vent length, 3" | 150 ft | 150 ft |
| Domestic hot water | Integrated in the combi heat exchanger | Integrated in the combi heat exchanger |
Both are NCB-H wall-hung combis rated 95.0% AFUE in the same 17.3 x 29.3 x 12.8 in cabinet, with dual stainless heat exchangers and on-demand DHW. The 240/110H crosses into the 240-class: 13 to 110 MBH heating against 11 to 80 MBH on the 190/080H.
The DHW side also steps up between classes, from 10,700 to 160,000 BTU/h on the 190-class models to 13,300 to 199,900 BTU/h on the 240-class pair. Households whose simultaneous hot-water draws push against the 190-class range are the ones that benefit from the larger DHW rating.
The 240/110H weighs 96 lb against 87 lb and its minimum fire rises from 11 to 13 MBH, so in a very low-load home the 080H tracks mild weather slightly more closely. Venting (2" to 65 ft, 3" to 150 ft) and the 1" NPT heating connections are unchanged across the step.
Navien
The Navien NCB-190/080H steps the NCB-H combi up to 11 to 80 MBH heating input with the same 160,000 BTU/h DHW input as the 060H, rated 95.0% AFUE in the identical 87 lb cabinet.
Navien
The Navien NCB-240/110H heats from 13 to 110 MBH input with DHW input from 13,300 to 199,900 BTU/h, rated 95.0% AFUE in the 96 lb NCB-H cabinet — the size most often matched to a detached home.
DHW input rises from 160,000 to 199,900 BTU/h on the 240-class models. The larger rating supports heavier or more frequent hot-water draws.
Yes, 96 lb against 87 lb. The cabinet dimensions are identical.
The 110H earns its place when the heat-loss calculation exceeds 80 MBH or the DHW demand needs the 240-class range. Below those, the 190/080H's lower minimum fire and lighter weight usually win.
A consultation includes a heat-loss review so the size is right the first time.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.