Skip to content
Boilers.caby ROMA Heating & Cooling

Navien · NCB-H Combi

Navien NCB-240/110H

The Navien NCB-240/110H heats from 13 to 110 MBH input with DHW input from 13,300 to 199,900 BTU/h, rated 95.0% AFUE in the 96 lb NCB-H cabinet — the size most often matched to a detached home.

CurrentSold in Canada

Key figures

Max input
110 MBH
Max CSA output
—
AFUE
95 %
Min input
13 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Navien NCB-240/110H in practice

The NCB-240/110H is the model a heat-loss calculation lands on for many detached Lower Mainland homes: 13 to 110 MBH of space-heating input with the DHW side firing from 13,300 to 199,900 BTU/h. Minimum fire rises to 13 MBH on the 240-class models, which is still low enough for steady part-load running in shoulder seasons.

It shares the 17.3 x 29.3 x 12.8 in footprint of the 190-class models but weighs 96 lb, and it carries the same dual stainless heat exchangers, 95.0% AFUE rating and 2" or 3" venting to 65 or 150 equivalent feet. The larger DHW range is what separates it from the 190-class models for households with heavier hot-water draws.

Best suited to

  • Detached homes whose heat-loss calculation needs between 80 and 110 MBH
  • Households wanting the 199,900 BTU/h DHW range of the 240-class combis
  • Replacing a mid-size older combi or boiler-plus-tank arrangement

Applicability and support

Model number
NCB-240/110H
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Navien. Units are shown with every value; notes flag conflicting sources or missing figures.

Navien NCB-240/110H specifications
SpecificationValueNote
Input
Heating input, minimum13 MBHSpace-heating input.
Heating input, maximum110 MBHSpace-heating input.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE per the installation manual.
Domestic hot water
DHW input, minimum13.3 MBH13,300 BTU/h
DHW input, maximum199.9 MBH199,900 BTU/h
Domestic hot waterIntegrated in the combi heat exchanger
Venting and air
VentingPVC, CPVC or approved polypropylene; 2" or 3"Canada: plastic venting must meet ULC S636 where required.
Max. equivalent vent length, 2"65 ft
Max. equivalent vent length, 3"150 ft
Physical and connections
Weight96 lbEmpty; per the installation manual.
Width17.3 in
Height29.3 in
Depth12.8 in
Gas connection3/4" NPT
Heating water connections1" NPT
Operating limits and other
FuelNatural gas or propaneSeparate Navien ratings per fuel.
Altitude rating10,100 ftPer installation manual.
System water pressure12 – 30 psi

Frequently asked questions

What are the heating and DHW inputs of the NCB-240/110H?

The installation manual lists 13,000 to 110,000 BTU/h of heating input and 13,300 to 199,900 BTU/h of DHW input, with 95.0% AFUE.

How much heavier is the NCB-240/110H than the 190-class models?

96 lb against 87 lb, per the installation manual. The cabinet dimensions are the same 17.3 x 29.3 x 12.8 in.

Is the NCB-240/110H a combi boiler?

Yes. Like every NCB-H it combines space heating with on-demand domestic hot water through its built-in DHW module, so no separate tank is needed.

Questions about the Navien NCB-240/110H?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate