Navien NCB-240/110H vs NTI Trinity FTVN110C

Verdict in brief

The Navien NCB-240/110H and NTI Trinity FTVN110C are both 95% AFUE wall-hung combis with 110 MBH-class heating, but their hot-water engines differ: Navien feeds DHW with up to 199.9 MBH of input while NTI publishes 2.7 GPM continuous delivery at a 77°F rise. Navien weighs 96 lb in a 12.8-inch-deep cabinet; NTI weighs 107 lb with 100 feet of 2" venting. Heat-loss first, DHW draw second.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Navien NCB-240/110H and NTI Trinity FTVN110C
SpecificationNavien NCB-240/110HNTI Trinity FTVN110C
Heating input, minimum13 MBH11 MBH
Heating input, maximum110 MBH110 MBH
Efficiency (AFUE)95 %95 %
FuelNatural gas or propaneNatural gas or propane
Weight96 lb107 lb
Max. equivalent vent length, 2"65 ft100 ft
Max. equivalent vent length, 3"150 ft150 ft
Gas connection3/4" NPT3/4" NPT
Heating water connections1" NPT1 1/4" NPT
Domestic hot waterIntegrated in the combi heat exchangerIntegrated combi (DHW plate) in the appliance

What actually separates them

Both are 95% AFUE wall-hung combi boilers (Navien prints 95.0%) listed for natural gas or propane, with heating inputs that land in the same band: Navien publishes 13 to 110 MBH for the NCB-240/110H and NTI publishes 11 to 110 MBH for the FTVN110C. Low-fire figures are close, which means neither boiler has a clear part-load advantage in a home whose calculated load sits well below 110 MBH.

Domestic hot water is where the two brands express themselves differently. Navien rates the DHW side by input — 13.3 to 199.9 MBH on the NCB-240/110H — while NTI publishes a delivery figure of 2.7 GPM continuous at a 77°F rise for the FTVN110C. A household sizing exercise compares the DHW input or delivery figure against its own draw pattern, which neither rating alone settles.

Packages and venting differ modestly: the NCB-240/110H weighs 96 lb and vents 2" to 65 feet or 3" to 150 feet per side with 1" NPT heating and 3/4" NPT gas connections, while the FTVN110C weighs 107 lb, allows 2" to 100 feet or 3" to 150 feet per side, and uses 1 1/4" NPT heating connections. Both produce DHW in the appliance, and both should be sized from a heat-loss calculation plus the household's peak hot-water draw.

CurrentSold in Canada
Input
13–110 MBH
Output (max)
—
AFUE
95 %

The Navien NCB-240/110H heats from 13 to 110 MBH input with DHW input from 13,300 to 199,900 BTU/h, rated 95.0% AFUE in the 96 lb NCB-H cabinet — the size most often matched to a detached home.

Natural gasPropaneCombi
CurrentSold in Canada
Input
11–110 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity FTVN110C is the smallest FTVN combi: it heats at 11 to 110 MBH input and delivers 2.7 GPM of continuous domestic hot water at a 77°F rise, all in the same 107 lb wall-hung cabinet as the heating-only FTVN110.

Natural gasPropaneCombi

Frequently asked questions

How do these combis compare on hot water?

Navien documents the NCB-240/110H's DHW input up to 199.9 MBH, while NTI documents 2.7 GPM continuous delivery at a 77°F rise for the FTVN110C — different rating styles that both need checking against the home's draws.

Which combi is lighter?

The Navien NCB-240/110H weighs 96 lb against 107 lb for the NTI FTVN110C, a small difference for wall mounting.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.